AVH-P5200BT/XNUC
43
5
6
7
8
5
6
7
8
C
D
F
A
B
E
ASMAX value:
00000045 in this case
Error ratio:
0.742E-5 in this case
Check 2: Check RF level
<Check>
Check the “ASMAX value” on the test mode screen in the focus closed status in the test mode.
Check 3: Check measured values of error ratio
<Check>
Check the error ratio of a specified ID in the tracking closed status in the test mode.
TCD-782
ASMAX value on
test mode screen
0000 0029 or more
(check)
RF level requiring gain + 6dBup
(ASMAX level)
Remarks:
GGV1025
ASMAX value on
test mode screen
0000 0026 or more
(check)
RF level requiring gain + 6dBup
(ASMAX level)
NO.
1
2
Disc used
Spot to check
Rated value
GGV1025
ID : 200000
1.000E-3 or less
Remarks:
GGV1025
ID : 40000
1.000E-3 or less
NO.
1
2
TCD-782
ID : Home position
2.500E-3 or less
3
Disc used
Spot to check
Rated value