background image

owner’s manual

2

PRE-DEF Indicator(cooling and heating-
 type) 
or Fan-Only Indicator(cooling-only type)

Infrared Signal Receiver

Infrared Signal Receiver

Operation Lamp

Operation Lamp

Timer Indicator

Alarm Indicator

Alarm Indicator

Temporary Button

Temperature Indicator

Timer Indicator

PRE-DEF Indicator (cooling and heating-
 type) 
or Fan-Only Indicator (cooling-only type)

Do not operate the air conditioner with wet hands. 

An electric shock may occur. 

Do not touch the heat exchanger fins. 

These fins are sharp and could result in cutting injuries.

Do not place items which might be damaged by moisture 
underneath the indoor unit. 

Condensation  may  form  if  the  humidity  is  above  80%,  the 
drain outlet is blocked, or the filter is polluted. 

After  extended  use,  check  the  unit  stand  and  fitting  for 
damage.

 

If the stand is damaged, the unit may fall and result in injury.

To avoid the risk of oxygen deficiency, ventilate the room 
sufficiently  if  any  equipment  with  a  burner  is  used 
together with the air conditioner.

Arrange the drain hose to ensure smooth drainage.

Incomplete  drainage  may  cause  wetting  of  the  building, 
furniture, etc.

Never touch the internal parts of the controller.

 

Do  not  remove  the  front  panel.  Some  parts  inside  are 
dangerous to touch, and machine trouble may happen.

Never expose little children, plants, or animals directly to 
the air flow. 

Adverse harmful effects to little children, animals, and plants 
may result.

Do not allow children to climb onto the outdoor unit, or 
to place an object on top of it.

 

Falling or tumbling may result in injury.

Do  not  operate  the  air  conditioner  when  using  room 
fumigation-type insecticide. 

Failure to observe this precuation could cause the chemicals 
to  become  deposited  in  the  unit,  which  could  endanger  the 
health of those who are hypersensitive to chemicals.

Do  not  place  appliances  which  produce  open  fire  in 
places exposed to the air flow from the unit, or under the 
indoor unit.

 

It  may  cause  incomplete  combuston,  or  deformation  of  the 
unit, due to the heat.

Do  not  install  the  air  conditioner  in  any  place  where 
flammable gas may leak out. 

If  the  gas  leaks  out  and  stays  around  the  air  conditioner,  a 
fire may break out. 

The appliance is not intended for use by young children 
or infirm persons without supervision.
 
This  appliance  can  be  used  by  children  aged  from  8  
years  and  above,  along  with  persons  with  reduced 
physical,  sensory  or  mental  capabilities,  or  lack  of 
experience  and    knowledge,  if  they  have  been  given 
supervision  or  instruction  concerning  use  of  the 
appliance  in  a  safe  way,  and  understand  the  hazards 
involved.  Children  shall  not  play  with  the  appliance. 
Cleaning  and  user  maintenance  shall  not  be  made  
by  children  without supervision.

This  appliance  is  not  intended  for  use  by  persons  
(including  children)  with reduced physical, sensory,  or  
mental  capabilities,  or  lack  of  proper experience  and  
knowledge, unless  they  have  been given  supervision  
or  instruction  concerning  use  of  the appliance,  by  a  
person  responsible  for their safety.

Children should be supervised to ensure that they do not 
play with the appliance. 

2.    TEMPORARY  OPERATIONS

The air conditioner consists of the indoor unit, the outdoor unit, 
the connecting pipe and the remote controller.

(See Fig. 1)

Function Indicators on Indoor Unit Display Panel

Display Panel

    

Fig. 2-1

    

Display Panel

    

Fig. 2-2

    

Display Panel

    

Fig. 2-3

    

NOTE: DEF Indicator (cooling and heating-type) 
or FAN Indicator (cooling-only type)

INFRARED SIGNAL RECEIVER

MANUAL

MANUAL

TIMER

ALARM

OPERATION

DEF./FAN

If the supply cord is damaged, it must be replaced by the 
manufacturer,  its  service  agent,  or  similarly  qualified 
persons, in order to avoid a hazard.

Do not operate your air conditioner in a wet room, such 
as a bathroom or laundry room.

Summary of Contents for UB018

Page 1: ...s air conditioner Before attempting to use your air conditioner please read this manual carefully and store it for future reference Ceiling Floor Type Ductless Split Systems UB018 UB024 UB036 UB048 Indoor Units UYB018 UYB024 UYB036 UYB048 System Sets ...

Page 2: ...ithin INDOOR UNIT OUTDOOR UNIT 1 2 3 5 4 7 6 8 8 9 All graphics in this manual are for explanatory purposes only There may be slight differences from the air conditioner that you purchased dependent on model The actual shape shall prevail NOTE RESE T TIM E ON TIM E OFF CLO CK SW ING AIR DIRE CTIO N OK ECO SW ING MO DE FAN SPE ED M LOCK C H AU TO CO OL DR Y HE AT FAN TEM P SE T CLOC K SET HOU R FAN...

Page 3: ...ection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can eventually leak into the groundwater and get into the food chain damaging your health and well being To prevent refrigerant leak contact your dealer When the system is installed and runs in a small room it is required to keep the concentration of the refrigerant if by any chance it leak...

Page 4: ... of those who are hypersensitive to chemicals Do not place appliances which produce open fire in places exposed to the air flow from the unit or under the indoor unit It may cause incomplete combuston or deformation of the unit due to the heat Do not install the air conditioner in any place where flammable gas may leak out If the gas leaks out and stays around the air conditioner a fire may break ...

Page 5: ...chieved when within these operating temperature ranges 2 3 NOTE FORCED AUTO The OPERATION lamp is lit and the air conditioner will run under FORCED AUTO mode The remote controller operation is enabled to function according to the received signal 1 FORCED COOL The OPERATION lamp flashes the air conditioner will turn to FORCED AUTO after it is set to cool with a wind speed of HIGH for 30 minutes The...

Page 6: ...e you restart the unit to ensure a smooth opera tion A clogged air filter will reduce cooling or heating efficiency therefore it s important to clean it once every two weeks With this new technology the display area will show EC if applicable and the LED indication lamps will continue flashing when the outdoor unit detects refrigerant leakage Louver Angle Memory Function optional For some models t...

Page 7: ...sed to clean the indoor unit if it is very dirty Never use a damp cloth on the remote controller Do not use a chemically treated duster for wiping or leave any such material on the unit for long as it may damage or cause fading on the surface of the unit Do not use benzene paint thinner polishing powder or similar solvents for cleaning Do not dry out the air filter underneath direct sunshine 14 16...

Page 8: ...2 Indoor Unit Outdoor Unit A continuous low hissing noise is heard when the system is in operation This is the sound of refrigerant gas flowing through both the indoor and outdoor units A hissing sound is heard at the start or immediately after stopping operation or beginning a defrosting operation This is the noise of refrigerant caused by flow stoppage or flow change Symptom 4 3 Outdoor Unit Whe...

Page 9: ...it OFF E9 Other malfunction of twins model OFF 9 Communication malfunction between indoor and outdoor units OFF E1 10 11 12 13 Discharging air temperature sensor error F3 Outdoor EEPROM error F4 Communication malfunction between two indoor units for twins model E8 OFF F0 1 10 9 7 6 5 4 2 1 Current overload protection Indoor EEPROM error E0 OFF 14 15 16 17 18 19 20 21 22 Outdoor fan speed malfuncti...

Page 10: ...s malfunction Voltage is too high or too low System circuit is blocked Outdoor unit and or indoor unit heat exchanger is dirty The air filter is dirty Inlet outlet of indoor outdoor units has blockage Doors and windows are open Sunlight is shine directly onto unit Too many heat sources within the area Outdoor temp is too high Leakage of refrigerant or lack of refrigerant Wait for the return of pow...

Page 11: ...eiver of the indoor unit when the ON OFF button is pressed Directly transmit the signal transmitter of the remote controller to the infrared signal receiver of the indoor unit and then repeatly push the ON OFF button twice The indication on the display disappears after a lapse of time Check whether the timer operation has come to an end when the TIMER OFF is indicated on the display The air condit...

Page 12: ...NW 102 Place Doral FL 33172 Phone 305 513 4488 www pd hvac com 16122700000010 20170328 The design and specifications of this product are subject to change without prior notice as development continues Consult with the sales agency or manufacturer for details ...