VSX-D307
4
A
B
C
D
1
2
3
4
1
2
3
4
G
•
NOTE FOR FUSE REPLACEMENT
FOR CONTINUED PROTECTION AGAINST RISK OF FIRE.
REPLACE WITH SAME TYPE AND RATINGS ONLY.
CAUTION -
AC
POWER
CORD
RY901:
POWER RELAY
Y10 (YJ6HW2-20-35/35)
Y11 (YJ6HW4-20-35/35)
Y12 (YJ6HW1-20-35/35)
VOLTAGE SELECTOR
AKX1004
CN951
POWER
TRANSFORMER
ATS7206
VOLTAGE SELECTOR
AKX-507
0 V
10V
120V
120V
110V
0 V
0 V
Y13 (YJ6HW2-25-35/35)
Y9 (YJ6HW1-25-35/35)
Y3 (YJ6HW6-25-35/35)
Y7 (YJ6HW0-20-35/35)
Y4 (YJ6HW9-20-35/35)
Y8 (YJ6HW2-20-35/35)
Y6 (YJ6HW8-20-35/35)
Y5 (YJ6HW4-20-35/35)
FU1
10A
FU2
4A
FU3
4A
2. SCHEMATIC DIAGRAM
2.1 FRONT ASSY
Note : When ordering service parts, be sure to refer to "EXPLODED VIEWS
and PARTS LIST" or "PCB PARTS LIST".
FRONT ASSY (AWX7075)
÷
The differences of adjacencies to Key switches
R541
1K
D515
1SS254
PRIMARY ASSY (AWX7073)
2.2 PRIMARY ASSY