XC-IS21MD
61
Step No.
Operation Keys and Operation Method
FL Display
Status
Remarks
1
Short circuit MECH TEST MODE during the power
EJECT
Test mode
ON.
(Fig.6-1)
2
Insert the test disc GGF1328 (MMD-212).
LOADING
GRT AJST
3
Press the NAME key
deFO AJST
(until deFO AJST is displayed).
4
Press the PLAY key.
PEG :
Defocus mode is entered, and after automatic
FESpp :
execution of normal adjustment, the C1 error at
of000c0015
the time of focus offset 0 is displayed.
5
Check the jitter value and end the adjustment when
the intermediate jitter value is 29 nsec or less.
6
Press the REC key.
of+04 c0032
The C1 error with application of a focus offset of
about 0.4
µ
m on the + side is displayed.
The jitter value (J+) at this time is recorded.
Step No.
Operation Keys and Operation Method
FL Display
Status
Remarks
1
Short circuit MECH TEST MODE during the power
EJECT
Test mode
ON.
(Fig.6-1)
2
Insert the test disc GGF1328 (MMD-212).
LOADING
GRT AJST
3
Press the NAME key (until AUTO AJST is displayed).
AUTO AJST
Normal adjustment mode
4
Normal adjustment starts when the PLAY key is pressed.
PEG :
HAG:
|
Can't ADJ.
Defective adjustment
(problem with the servo system)
COMPLETE
Adjustment end
5
Press the STOP key.
AUTO AJST
Return to menu display
5
Normal adjustment
6
Defocus adjustment
Step No.
Operation Keys and Operation Method
FL Display
Status
Remarks
3
Press the NAME key (until AUT YOBI is displayed).
AUT YOBI
Preliminary adjustment mode
4
Preliminary adjustment starts when the PLAY key is
HAo :
pressed.
RFg :
PTG :
|
Can't ADJ.
Defective adjustment
(problem with the servo system)
COMPLETE
Adjustment end
5
Press the STOP key.
AUT YOBI
Return to menu display
6
Power OFF
EEPROM W
Writing to the EEPROM
GGF1328
(MMD-212)
4
Preliminary Adjustment
Note: When this adjustment is performed after defocus adjustment has been performed, defocus is returned to the initial status, and defocus
adjustment must be performed.
of c
Deforcus Value
C1 Error Value