TABLE VIIIA-II. ENGINE TROUBLESHOOTING (cont.)
High oil temperature.
Insufficient oil supply.
Fill oil sump to proper
(cont.)
level with specified oil.
Low grade of oil.
Replace with oil con-
forming to specifica-
tions.
Clogged oil lines or
Remove and clean oil
strainers.
strainers.
Excessive blow-by.
Usually caused by worn
or stuck rings.
Failing or failed
Examine sump for
bearing.
metal particles. If
found, overhaul of en-
gine is indicated.
Defective temperature
Replace gauge.
gauge.
Excessive oil consump-
Low grade of oil.
Fill tank with oil con-
tion.
forming to specifica-
tions.
Failing or failed bear-
Check sump for metal
ings.
particles.
Worn piston rings.
Install new rings.
Incorrect installation of
Install new rings.
piston rings.
Failure of rings to seat
Use mineral base oil.
(new nitrided cylind-
Climb to cruise altit-
ers.)
ude at full power and
operate at 75% cruise
power setting with high
oil temperature until
oil consumption stabil-
izes.
Trouble
Cause
Remedy
Revised: 8/31/77
CHEROKEE ARROW III SERVICE MANUAL
POWER PLANT - LYCOMING
Summary of Contents for ARROW III
Page 4: ...THIS PAGE INTENTIONALLY LEFT BLANK 1A4...
Page 12: ...THIS PAGE INTENTIONALLY LEFT BLANK 1A12...
Page 94: ...Figure 4 2 Wing Installation Revised 2 13 89 1D22 CHEROKEE ARROW III SERVICE MANUAL STRUCTURES...
Page 171: ...lH3 INTENTIONALLY LEFT BLANK...
Page 172: ...lH4 INTENTIONALLY LEFT BLANK...
Page 286: ...THIS PAGE INTENTIONALLY LEFT BLANK Revised 2 13 89 2A8...
Page 528: ...INTENTIONALLY LEFT BLANK 2K10 THRU 2L24 2K10...