2I22
TABLE XI-V. ELECTRICAL SYSTEM TROUBLESHOOTING (cont)
Motor fails to operate.
Binding, worn, or
CAUTION
(cont)
improperly seated
brush, or brushes with
Do not use coarse sandpaper
excessive side play.
or emery cloth. After seating,
(cont)
clean thoroughly to remove
all sand and metal particles
to prevent excessive wear.
Keep motor bearing free from
sand or metal particles.
Dirty commutator.
If commutator is rough or
dirty, smooth and polish
with number 0000 sandpaper.
If too rough and pitted,
remove and turn down.
Blow out all particles.
Shorted, grounded, or
Remove and replace with
open armature.
an armature known to be
in good condition.
Grounded or open
Test, repair if possible or
field circuit.
replace with a new part.
Low motor and cranking
Worn, rough, or
Disassemble, clean,
speed.
improperly lubricated
inspect, and relubricate,
motor or starter
replace ball bearings
gearing.
if worn.
Same electrical causes
Same remedies listed for
as listed under “Motor
these troubles.
Fails to Operate.”
Trouble
Cause
Remedy
Revised: 2/13/89
CHEROKEE ARROW III SERVICE MANUAL
ELECTRICAL SYSTEM
STARTER (cont)
Summary of Contents for ARROW III
Page 4: ...THIS PAGE INTENTIONALLY LEFT BLANK 1A4...
Page 12: ...THIS PAGE INTENTIONALLY LEFT BLANK 1A12...
Page 94: ...Figure 4 2 Wing Installation Revised 2 13 89 1D22 CHEROKEE ARROW III SERVICE MANUAL STRUCTURES...
Page 171: ...lH3 INTENTIONALLY LEFT BLANK...
Page 172: ...lH4 INTENTIONALLY LEFT BLANK...
Page 286: ...THIS PAGE INTENTIONALLY LEFT BLANK Revised 2 13 89 2A8...
Page 528: ...INTENTIONALLY LEFT BLANK 2K10 THRU 2L24 2K10...