TABLE XIV-IV. TROUBLESHOOTING CHART (AIR CONDITIONER) (cont)
Gauge Indication
Probable Causes
Remedy
Low suction pressure.
Low air supply through
Repair blower or blower
(Accompanied by icing
evaporator.
motor. Clean stoppage
evaporator.)
in air ducts.
Very dirty evaporator
Clean and flush with
fins and coils.
water.
Low suction pressure.
Undercharge of refrigerant.
Add refrigerant. Install
(Evaporator not cold
Moisture freezing in ex-
new dryer. Evacuate
enough) suction gauge
pansion valve. Valve will
may read a vacuum
show frost. Expansion
indicating evaporator
valve inlet screen clogged.
lacks refrigerant.
Inoperative expansion
Remove screen. Clean
valve. Valve stuck closed
with solvent and replace.
or capillary bulb has lost
Warm capillary by holding
its charge.
in hand. If suction pressure
does not charge, replace
pansion valve.
Restriction anywhere in
Locate restriclion and
liquid line. Restriction
repair.
will show first.
High suction pressure.
Capillary bulb clamp loose
Clean contact surfaces of
on suction line. Suction
suction line and cap bulb.
line shows frost.
Tighten clamp.
Expansion valve not
Replace expansion valve.
closing. Evaporator
flooded. Suction line
frosted to compressor.
Compressor drive belt
Adjust belt tension,
slipping.
Revised: 2/13/89
3B17
CHEROKEE ARROW III SERVICE MANUAL
ACCESSORIES AND UTILITIES
Summary of Contents for ARROW III
Page 4: ...THIS PAGE INTENTIONALLY LEFT BLANK 1A4...
Page 12: ...THIS PAGE INTENTIONALLY LEFT BLANK 1A12...
Page 94: ...Figure 4 2 Wing Installation Revised 2 13 89 1D22 CHEROKEE ARROW III SERVICE MANUAL STRUCTURES...
Page 171: ...lH3 INTENTIONALLY LEFT BLANK...
Page 172: ...lH4 INTENTIONALLY LEFT BLANK...
Page 286: ...THIS PAGE INTENTIONALLY LEFT BLANK Revised 2 13 89 2A8...
Page 528: ...INTENTIONALLY LEFT BLANK 2K10 THRU 2L24 2K10...