3B21
TABLE XIV-IV. TROUBLESHOOTING CHART (AIR CONDITIONER) (CONT)
Excessively noisy
Electrical
system. (cont)
Compressor noisy.
Check mounting and repair;
remove compressor for
service or replacement,
14-18.
Compressor oil level
Fill with correct amount
low.
Refrigeration
Excessive charge in
Discharge excess freon until
system.
high pressure gauge drops
within specifications.
Low charge in system.
Check system for leaks;
charge system, 14-9 and
14-14.
Excessive moisture in
Replace dehydrator, purge,
system.
evacuate, and charge system,
14-32, 14-13 and 14-14.
Trouble
Cause
Remedy
Revised: 2/13/89
CHEROKEE ARROW III SERVICE MANUAL
ACCESSORIES AND UTILITIES