Is there an alternate communication protocol if FTP communication is restricted on my
network?
Some meters support using HTTPS as an alternative to FTP. If your meter supports this communication,
use the Internet Settings menu from PC Meter Connect and select HTTPS mode. If the feature is not
supported, the option is greyed out.
What type of communication does the meter use while connecting to the Pitney Bowes Data
Centre servers?
The meter uses HTTP on Port 80, HTTPS on Port 443, and FTP on Port 21 for communications to
Pitney Bowes Data Centre Servers. Port 80 is used to communicate XML formatted messages
requesting services.
NOTE:
For HTTPS downloads, the ports depend on the supported security for both the client and target server. If
Secure Sockets Layer (SSL) is used, all communication will be on port 443. If the client and host server support
Transport Layer Security (TLS), TLS is used by PC Meter Connect desktop application. If TLS is used, port 443
is used for the server, but the client will use a random higher level port.
Does the System use static and dynamic addressing?
PC Meter Connect uses the PC’s internet connection and functions with static or dynamic IP addressing.
Is the HTTP communication “Chunked” or “Non-Chunked”?
The PC Meter Connect desktop application supports both “chunked” and “non-chunked” HTTP transfer
encoding communication. By default, the PC Meter Connect uses “non-chunked”. However, Postage by
Phone connectivity can be easily changed using the
You should only make this change if necessary. Most networks will function properly with the default,
Non-Chunked setting.
My network is connected to the internet via a Proxy. How do I set PC Meter Connect desktop
application to use the same Proxy?
NOTE:
If you have PC Meter Connect installed on your system already, when you connect your mailing machine
to the PC it determines whether you have the full PC Meter Connect desktop application or only the Proxy
version.
If your communications are routed through a proxy, you must set up the PC Meter desktop application to
access the proxy. Use the
screen to set up the PC Meter Connect application to
Using PC Meter Connect
Pitney Bowes
Operator Guide
February, 2017
Page 154 of 226
Summary of Contents for DM125
Page 4: ......
Page 16: ...This page intentionally left blank ...
Page 24: ...This page intentionally left blank ...
Page 65: ...7 How to Enter Text About Entering Text 66 ...
Page 68: ...This page intentionally left blank ...
Page 118: ...This page intentionally left blank ...
Page 128: ...This page intentionally left blank ...
Page 129: ...12 Passwords About Passwords and Meter Functions 130 ...
Page 146: ...This page intentionally left blank ...
Page 191: ...17 Supplies and Options Supplies and Options 192 ...
Page 194: ...This page intentionally left blank ...
Page 195: ...18 Specifications Specifications Equipment and Materials 196 ...
Page 198: ...This page intentionally left blank ...
Page 223: ...20 Glossary ...