Troubleshooting
Overview
Telephony Gateway Reference Manual
504
Client is installed in on the PC, and the host standard error is
redirected to a file on the EDGE server.
4.
Reproduce the problem.
5.
Return the EDGEO.INI to its original state.
Setting ASCII
Standard Error
To set standard error for an ASCII agent, perform the following steps:
1.
Find the following lines in the EDGE .profile file (located in
$EDGE):
exec $EDGESYS/bin/starthere UPDDVR EDGE -L 2>/dev/null
# exec $EDGESYS/bin/starthere UPDDVR EDGE -L 2>$HOME/tmp/err.$$.
2.
Move the number sign (#) that indicates the second line is a
comment, to the first line. The two lines should appear as fol-
lows:
#exec $EDGESYS/bin/starthere UPDDVR EDGE -L 2>/dev/null
exec $EDGESYS/bin/starthere UPDDVR EDGE -L 2>$HOME/tmp/err.$$.
3.
Log out of EDGE and then log back in. The agent’s standard
error is now directed to a file named err.PID (process ID num-
ber) in the $EDGE/tmp directory.
4.
Reproduce the problem.
5.
Return the .profile to its original state.
Summary of Contents for EDGE 7.11
Page 1: ...EDGE 7 11 Telephony Gateway Reference Manual ...
Page 8: ...How to Use This Manual Telephony Gateway Reference Manual 8 ...
Page 210: ...Dialer Setup Callset Area Telephony Gateway Reference Manual 210 ...
Page 221: ...Dialer Setup Callset Area Telephony Gateway Reference Manual 221 ...
Page 237: ...Dialer Setup Callset Area Telephony Gateway Reference Manual 237 white text ...
Page 368: ...Open Campaign Telephony Gateway Reference Manual 368 Call processor ID Initialize files ...
Page 390: ...Send User Data Telephony Gateway Reference Manual 390 ...
Page 601: ...Environment Variables List of Environment Variables Telephony Gateway Reference Manual 601 ...
Page 638: ...CallPath Overview Telephony Gateway Reference Manual 638 CallPath Setup CallPath Messages ...
Page 724: ...SER SER Setup Telephony Gateway Reference Manual 724 START LENGTH 1 19 ...