background image

 

 

 

 

Operating 

Instructions  for 

Electrical Heater Units 

 

 

PITSAN 

 

Page 16 / 16 

 

 

PİTSAN MAK. SAN. VE TİC. LTD ŞTİ, 

Esenyurt Yolu Üzeri No: 66 - 68 Bağlar Mevkii,  TR – 34850 Avcılar - İSTANBUL

 

Tel.: 0212/4281885, Fax: 0212/4281661, Email:

pitsan@pitsan.com

http: //www.pitsan.com

 

 

EC DECLARATION OF CONFORMITY 

 

MANUFACTURER 

 

NAME  

 

: PITSAN MAKINA SAN. VE TIC. LTD.STI. 

ADDRESS

 

: ESENYURT YOLU, BAGLAR MEVKII, NO:66/68 AVCILAR- ISTANBUL 

TEL

 

 

: 0212 4281885  

FAX :

  0212 4281661  

WEB:

   pitsan@pitsan.com 

 
 
The undersigned declares that the described products meet the essential requirements of the 
below mentioned standards as based on EN 60335-1; EN 60335-2-33 
 
The  item  of  equipments  which  identified  below  has  been  subject  to  internal  manufacturing 
checks with monitoring of the final assesment by PITSAN 

 
MACHINE MODEL LIST 

:  ETA /EKI series electrical heating units 

 
 

 

APPLICABLE DIRECTIVES

 :  

 
2006/ 42 / EC MACHINERY SAFETY DIRECTIVE 
2006 / 95 / EC LOW VOLTAGE DIRECTIVE  
2004 / 108/ EC ELECTROMAGNETIC COMPATIBILITY DIRECTIVE 
 

APPLICABLE REGULATIONS :  

 
EN 614-1:2006 ; EN 894-2:1997+A1:2008 ; EN 953:1997 ; EN 983:1996 + A1:2008 ;  
EN 1037:

 

1995 + A1:2008 ; EN 1088:

 

1995 + A2:2008 ; EN 11200:1995 ; EN 12100-1:2003 ;  

EN 12100-2:2003 ; EN ISO 13849-1:2008 ; EN ISO 13850:2008 ; EN ISO 14121-1:2007 ;  
EN 60204-1:2006 ; EN 13985:2003 ; EN 999:1998 +A1:2008 ; EN 982:1996 +A1:2008 ;  
EN 894-3:2000+A1:2008 ; EN 894-1:1997+A1:2008 ; EN 349+A1:2008 ; EN ISO 13857:2008 
;  
EN 12622:2001 ; EN 61000-6-2:2005 ; EN 61000-6-4:2007 

 
EC CERTIFICATE NO/ NOTIFIED BODY: 

 

Sertifika Numarası Verilebilir. 

 
SIGNED ON BE HALF OF THE MANUFACTURER  

 
NAME   

            :  

POSITION 

 

:  

PLACE/ DATE 

: ..........  / ……. 

SIGNATURE   

 
 
 
 
 

Summary of Contents for EKI 400x200-10.5-3/3x3.5 kw

Page 1: ...senyurt Yolu zeri No 66 68 Ba lar Mevkii TR 34850 Avc lar STANBUL Tel 0212 4281885 Fax 0212 4281661 Email pitsan pitsan com http www pitsan com INSTALLATION OPERATION MAINTENANCE INSTRUCTIONS ELECTRIC...

Page 2: ...n com CONTENTS 1 GENERAL 3 2 SAFETY 3 2 1 Safety instructions 3 2 2 Correct use 3 3 DESCRIPTION OF THE UNIT 5 4 OPERATING PRINCIPLE 7 5 APPLICATION AND INTENDED USE 7 6 PACKAGING HANDLING STORAGE 8 7...

Page 3: ...ccordance with local electrical codes This equipment requires a ground as precaution against electrical shock Basic precautions should always be followed to reduce the risk of fire electric shock and...

Page 4: ...working properly in threephase models Hot Furface The surface temperature of the heater may rise up to temperatures which will cause inquiry Do not touch the surface while the heater is operating In...

Page 5: ...PITSAN Page 5 16 P TSAN MAK SAN VE T C LTD T Esenyurt Yolu zeri No 66 68 Ba lar Mevkii TR 34850 Avc lar STANBUL Tel 0212 4281885 Fax 0212 4281661 Email pitsan pitsan com http www pitsan com 3 DESCRIPT...

Page 6: ...ater Units PITSAN Page 6 16 P TSAN MAK SAN VE T C LTD T Esenyurt Yolu zeri No 66 68 Ba lar Mevkii TR 34850 Avc lar STANBUL Tel 0212 4281885 Fax 0212 4281661 Email pitsan pitsan com http www pitsan com...

Page 7: ...evices that rotate the fan to move the heated air from the heater to the space When the unit heater wattage is over loaded one or more CONTACTORS are employed to switch the electrical current to the e...

Page 8: ...ents on pallets It is essential that great care is exercised when handling the unit When handling the equipment care should be taken with corners and edges and that the weight distribution within the...

Page 9: ...imum recommended mounting height to bottom of heater 4 5meters Minimum clearance from walls and ceiling are Z 250mm VERTICAL DISCHARGE To ensure proper heating of floor surfaces observe the following...

Page 10: ...ctrical Heater Units PITSAN Page 10 16 P TSAN MAK SAN VE T C LTD T Esenyurt Yolu zeri No 66 68 Ba lar Mevkii TR 34850 Avc lar STANBUL Tel 0212 4281885 Fax 0212 4281661 Email pitsan pitsan com http www...

Page 11: ...ctrical Heater Units PITSAN Page 11 16 P TSAN MAK SAN VE T C LTD T Esenyurt Yolu zeri No 66 68 Ba lar Mevkii TR 34850 Avc lar STANBUL Tel 0212 4281885 Fax 0212 4281661 Email pitsan pitsan com http www...

Page 12: ...gh limits of the motor and or heater 9 Check out and repost any unusual or questionable operating characteristics such as noise vibration etc 10 Set the fan switch and temperature control on desired o...

Page 13: ...lectrical cable insulations contactors to avoid any short circuits Be sure that all clearances for air intake are kept as installation 10 POSSIBLE PROBLEM CAUSES AND SOLUTIONS PROBLEM POSSIBLE CAUSE S...

Page 14: ...ate of normal service when installed and operated in accordance with the instructions provided by the Company and subject to the following conditions 1 Since the paint finish may be damaged in use no...

Page 15: ...212 4281885 Fax 0212 4281661 Email pitsan pitsan com http www pitsan com 12 APPENDIX The customers confirm by their signatures that they have received read and understood the operating and maintenance...

Page 16: ...t to internal manufacturing checks with monitoring of the final assesment by PITSAN MACHINE MODEL LIST ETA EKI series electrical heating units APPLICABLE DIRECTIVES 2006 42 EC MACHINERY SAFETY DIRECTI...

Reviews: