M0313 it | en
58
/60
Installation, use and maintenance
16
DEMOLITION AND DISPOSAL
Foreword
If the system needs to be disposed, the parts which make it up must be delivered
to companies that specialize in the recycling and disposal of industrial waste and, in
particular:
Disposing of
packing mate-
rials
The packaging consists of biodegradable cardboard which can be delivered to com-
panies for normal recycling of cellulose.
Metal Parts
Disposal
Metal parts, whether paint-finished or in stainless steel, can be consigned to scrap
metal collectors.
Disposal of
electric and
electronic
components
These must be disposed of by companies that specialize in the disposal of electronic
components, in accordance with the indications of directive 2012/19/EU (see text of
directive below).
Infor-
mation
regard-
ing the
environment
for clients
residing within
the European
Union
European Directive 2012/19/EU requires that all equipment marked with this symbol
on the product and/or packaging not be disposed of together with non-differenti-
ated urban waste. The symbol indicates that this product must not be disposed of
together with normal household waste. It is the responsibility of the owner to dis-
pose of these products as well as other electric or electronic equipment by means
of the specific refuse collection structures indicated by the government or the local
governing authorities.
Disposing of RAEE equipment as household wastes is strictly forbidden. Such wastes
must be disposed of separately.
Any hazardous substances in the electrical and electronic appliances and/or the mis-
use of such appliances can have potentially serious consequences for the environ-
ment and human health.
In case of the unlawful disposal of said wastes, fines will be applicable as defined by
the laws in force.
Miscellaneous
parts disposal
Other components, such as pipes, rubber gaskets, plastic parts and wires, must be
disposed of by companies specialising in the disposal of industrial waste.
17
PROBLEMS AND SOLUTIONS
GENERAL NOTE:
Refer to section “M”, and in particular to the signals of the diagnostic LEDs for the most
common alarms managed by the electronic control system.
For any problems contact the authorised dealer nearest to you.
PROBLEMS
POSSIBLE CAUSE
POSSIBLE SOLUTION
THE MOTOR
DOES NOT
TURN
Lack of power
Check the electrical connections
Rotor blocked
Check possible damage or ob-
structions to the rotating parts
Problems with the motor
Contact technical assistance
department