Camera Operation & Features
33
PixeLINK PL-A780
Document No.: 04646-01
MACHINE VISION CAMERA
SYSTEM GUIDE
Copyright © 2004 PixeLINK
All Rights Reserved
5.1.3.7 Saturation
Auto No
Manual Yes
One-time
Auto
No
Off No
CiD No
Saturation controls the intensity of the hues in the image. The
saturation control allows the hue to be changed from full mono to
twice the normal hue.
Saturation is applicable to color cameras only.
Parameter Unit Type
Min
Max
Default
Step
Size
Comments
Alpha Percentage
Relative
0 250 100 1
5.1.3.8 Shutter
Auto Yes
Manual Yes
One-time
Auto
Yes
Off No
CiD Yes
Shutter controls the integration time of the sensor. The shutter can
be controlled manually, once automatically or fully automatically. In
the auto modes, the camera will attempt to set the shutter feature
such that a small portion of the scene is saturated.
In rolling shutter mode (See the Trigger feature, Section 5.1.3.10
on page 34), the Shutter control determines the number of lines in
the ROI that are active at any time. In Fast Reset Shutter mode,
the Shutter control determines the length of time from the
completion of frame reset to the start of readout.
When the Frame Rate control is active (ON), the Shutter control is
limited by the Frame Rate control setting. For example, if the
Frame Rate control is set to 50 fps, the maximum value of the
Shutter control will be limited to 20 ms. For unlimited control of the
Shutter feature, the Frame Rate control must be turned off.
Parameter Unit Type
Min
Max
Default
Step
Size
Comments
Integration
Time
Seconds Absolute 63
µs 2.0 0.1
Varies The integration time step size
is the time required to read
out one row. See Section