User manual - TCT101-2ABC
- 21
9.1.g Output duration configuration
26
o.dW.1
Output 1 Duration
Counter 1 output duration
user
Value modifiable by user.
Default
10.
Latc.
Latch output, resettable by counter loading
1
Output duration minimum value
999
Output duration maximum value
9.1.h Counter frequency display
configuration
27
di.f.1
Display Frequency Counter 1
Counter 1 frequency visualization
dis.
Disabled.
Default
Wisu .
Counter frequency value visualized
28
d.p.f.1
Decimal Point Frequency Counter 1
Counter 1 frequency format
0
Visualization with no decimal digit.
Default
.
0. 0
Visualization with 1 decimal digit
0. 00
Visualization with 2 decimal digits
0. 000
Visualization with 3 decimal digits
29
in.f.1
Counter 1 Input frequency
Counter 1 input frequency 1 (1..9999Hz).
Default
1.
30
vi.f.1
Counter 1 Visualized Frequency
Counter 1 visualized frequency (1..9999Hz).
Default
1.