with operator protection function additional requirements must be observed.
- The utilization implies knowledge of and compliance with following standards: 
EN ISO 13849-1, EN 62061, EN 60204-1, EN ISO 12100. 
- In the risk analysis, take into account that in manual start mode a possible sticking of 
the start button can lead to an immediate activation of the module.
- If expansion modules or external contactors are used, make sure that they have 
forcibly guided contacts and connect in feedback an NC contact of each device. 

7.6 Limits of use

- Use the device following the instructions, complying with its operation limits and the 
standards in force.
- The devices have specific application limits (min. and max. ambient temperature, 
maximum currents, IP protection degree, etc.) These limitations are met by the device 
only if considered individually and not as combined with each other. 
- According to EU directives, this device is not intended for private use.
- The manufacturer’s liability is to be excluded in the following cases:
1) Use not conforming to the intended purpose.
2) Failure to adhere to these instructions or regulations in force.
3) Fitting operations not carried out by qualified and authorized personnel.
4) Omission of functional tests.
- For the cases listed below, before proceeding with the installation contact our as-
sistance service (see paragraph SUPPORT):
a) In nuclear power stations, trains, airplanes, cars, incinerators, medical devices or 
any application where the safety of two or more persons depend on the correct opera-
tion of the device.
b) cases not listed in these operating instructions.

 8 MARKINGS

The outside of the device is provided with external marking positioned in a visible 
place. Marking includes:
- Producer trademark
- Product code
- Batch number and date of manufacture. Example: CS1-123456 (A19). The last part 
of the production batch refers to the month of manufacture (A = January, B = February, 
etc.) as well as the year of manufacture (19 = 2019, 20 = 2020, etc.).

 9 TECHNICAL DATA

9.1 Housing

Material: Polyamide PA 66, self-extinguishing V0 acc. to UL 94
Protection degree: 

IP40 (housing), IP20 (terminal strip)

Cable cross section: 

0.2 … 2.5 mm

 (24 … 12 AWG)

Terminal tightening torque: 

0.5 … 0.6 Nm

9.2 General data

SIL (SIL CL): 

Up to SIL CL 3 acc. to EN 62061

Performance Level (PL):  

Up to PL e acc. to EN ISO 13849-1

Safety category: 

Up to cat. 4 acc. to EN ISO 13849-1

MTTF

D

:  

227 years

DC:  

High

PFH

D

1.13 E-10

Mission time: 

20 years

Ambient temperature: 

-25°C … +55°C

Storage temperature: 

-25°C … +70°C

Mechanical endurance: 

> 10 million operating cycles

Electrical endurance: 

> 100,000 operating cycles

Pollution degree: 

external 3, internal 2

Impulse withstand voltage U

imp

4 kV

Rated insulation voltage U

i

250 V

Overvoltage category: 

II

Air and surface distances:  

acc. to EN 60947-1

9.3 Power supply

Rated supply voltage U

n

:  

24 Vac/dc; 50…60 Hz 

(articles CS AR-94•024)

 

12 Vdc 

(articles CS AR-94•U12)

Supply voltage tolerance:  

±15% of U

(articles CS AR-94•024)

 

-10 … +15% of U

(articles CS AR-94•U12)

Max. DC residual ripple in DC: 

10%

Power consumption AC: 

< 5 VA

Power consumption DC: 

< 2 W

9.4 Control circuit

Protection against short circuits: 

PTC resistance, Ih = 0.5 A

PTC times: 

Response time > 100 ms, release time > 

3 s
Maximum resistance per input:  

 25 

Ω 

(articles CS AR-94•024)

 

 15 

Ω 

(articles CS AR-94•U12)

Current per input: 

< 35 mA (articles CS AR-94•024)

 

< 65 mA (articles CS AR-94•U12)

Min. duration of start impulse t

MIN

> 300 ms

Response time t

A

< 130 ms

Release time t

R1

< 20 ms

Release time  
in absence of power supply t

R

:  

< 120 ms (articles CS AR-94•024)

 

< 70 ms (articles CS AR-94•U12)

Simultaneity time t

C

: unlimited

Response time starting from  

application of the supply: 

< 200 ms (articles CS AR-94•024)

 

< 400 ms (articles CS AR-94•U12)

9.5 Output circuit

Output contacts: 

2 NO safety contacts

Contact type: 

forcibly guided

Material of the contacts: 

gold-plated silver alloy

Maximum switching voltage: 

230/240 Vac; 300 Vdc

Max. current per contact: 

6 A

Conventional free air thermal current I

th

:  6 A

Max. total current 

Σ

 I

th

2

36 A

2

Minimum current: 

10 mA

Contact resistance: 

 100 m

External protection fuse: 

4 A

Maximum switching load: 

1380 VA/W

Utilization categories acc. to EN 60947-5-1: 

AC15 (50 … 60 Hz)  

U

= 230 V, I

= 3 A 

DC13 (6 op. cycles/minute)  

U

= 24 V, I

= 4 A

Utilization category acc. to UL 508: 

C300

9.6 Compliance with standards

EN 60204-1, EN ISO 13855, EN ISO 14118, EN ISO 12100, EN ISO 13850, EN 60529, 
EN 61000-6-2, EN 61000-6-3, EN 61326-1, EN 60664-1, EN 60947-1, EN IEC 63000, 
EN ISO 13849-1, EN ISO 13849-2, EN 62061, EN 81-20, EN 81-50, UL 508, 
CSA C22.2 n° 14-95, GB/T14048.5-2017

9.7 Compliance with directives

Machinery Directive 2006/42/EC, EMC Directive 2014/30/EU, Lifts Directive 2014/33/
EU, RoHS Directive 2011/65/EU.

 10 SPECIAL VERSIONS ON REQUEST

Special versions of the device are available on request.
These special versions may differ substantially from the indications in these operating 
instructions.
The installer must ensure that he has received written information regarding the use 
of the special version requested (see paragraph SUPPORT).

 11 DISPOSAL

At the end of service life product must be disposed of properly, according to the 
rules in force in the country in which the disposal takes place.

 12 SUPPORT

The device can be used for safeguarding people’s physical safety, therefore in case of 
any doubt concerning installation or operation methods, always contact our technical 
support service:
Pizzato Elettrica Srl
Via Torino, 1 - 36063 Marostica (VI) - ITALY
Tel39.0424.470.930 
E-mail tech@pizzato.com
www.pizzato.com
Our support service provides assistance in Italian and English.

 13 EC CONFORMITY DECLARATION

I, the undersigned, as a representative of the following manufacturer:
Pizzato Elettrica Srl - Via Torino, 1 - 36063 Marostica (VI) – ITALY 
hereby declare that the product is in conformity with whatever prescribed by the 
2006/42/EC Machine Directive and Lifts Directive 2014/33/EU. The complete version 
of the present conformity declaration is available on our website www.pizzato.com
Marco Pizzato

DISCLAIMER:
Subject to modifications without prior notice and errors excepted. The data given in this sheet 
are accurately checked and refer to typical mass production values. The device descriptions and 
its applications, the fields of application, the external control details, as well as information on 
installation and operation, are provided to the best of our knowledge. This does not in any way mean 
that the characteristics described may entail legal liabilities extending beyond the “General Terms of 
Sale”, as stated in the Pizzato Elettrica general catalogue. Customers/users are not absolved from 
the obligation to read and understand our information and recommendations and pertinent technical 
standards, before using the products for their own purposes. Taking into account the great variety of 
applications and possible connections of the device, the examples and diagrams given in the present 
manual are to be considered as merely descriptive; the user is deemed responsible for checking that 
the specific application of the device complies with current standards. This document is a translation 
of the original instructions. In case of discrepancy between the present sheet and the original copy, 
the Italian version shall prevail. The present manual may not be reproduced, in whole or in part, 
without the prior written permission by Pizzato Elettrica.
© 2019 Copyright Pizzato Elettrica. All rights reserved.

Summary of Contents for CS AR-94 Series

Page 1: ...2 e della tensione d alimen tazione Ingresso di muting o esclusione della funzione di sicurezza non presente In caso di guasto il dispositivo si porta in stato sicuro disattivando l uscita di sicu rez...

Page 2: ...ro Prima della messa in funzione assicurarsi che l intera macchina o il sistema sia conforme alle norme applicabili e ai requisiti della Direttiva Compatibilit Elettroma gnetica La documentazione nece...

Page 3: ...94 024 15 articoli CS AR 94 U12 Corrente per ingresso 35 mA articoli CS AR 94 024 65 mA articoli CS AR 94 U12 Durata minima impulso di start tMIN 300 ms Tempo di eccitazione tA 130 ms Tempo di ricadut...

Page 4: ...itching state of the channels 1 2 and for the power supply voltage Without muting input no bridging of the safety function In the event of a failure the device switches to a safe state and deactivates...

Page 5: ...French German and Italian Should the installer be unable to fully understand the documents the product must not be installed and the necessary assistance may be requested from the manufac turer see pa...

Page 6: ...application of the supply 200 ms articles CS AR 94 024 400 ms articles CS AR 94 U12 9 5 Output circuit Output contacts 2 NO safety contacts Contact type forcibly guided Material of the contacts gold...

Page 7: ...e et m thode de redondance Indicateurs LED de l tat de commutation des canaux 1 2 et de la tension d alimen tation Pas d entr e d inhibition pas d exclusion de la fonction de s curit En cas de d faill...

Page 8: ...dispositif Ne pas utiliser le dispositif comme support ou appui pour d autres structures che mins guides de glissement ou autres Avant la mise en service veiller ce que l ensemble de la machine ou le...

Page 9: ...9 4 Circuit de contr le Protection contre les courts circuits r sistance PTC Ih 0 5 A Temps de la PTC d clenchement 100 ms r armement 3 s R sistance maximale par entr e 25 articles CS AR 94 024 15 ar...

Page 10: ...rwachung und Redundanz LED Anzeigen f r den Schaltzustand der Kan le 1 2 und f r die Versorgungsspan nung Ohne Mutingeingang keine Unterdr ckung der Sicherheits Funktion Bei einer St rung geht das Ger...

Page 11: ...me die korrekte Funktion des Moduls gem den Angaben der Ablaufdiagramme pr fen siehe Abschnitt BETRIEB Die Anschlusskabel d rfen nicht berm ig verbogen werden um Kurzschl sse und Unterbrechungen zu ve...

Page 12: ...94 024 12 Vdc Artikel CS AR 94 U12 Versorgungsspannungstoleranz 15 von Un Artikel CS AR 94 024 10 15 von Un Artikel CS AR 94 U12 Max DC Restwelligkeit 10 Leistungsaufnahme AC 5 VA Leistungsaufnahme DC...

Reviews: