34
QM00992 - 1
PJLink command (continued)
Commands
Control Description
Parameter or Response
ERST ?
Error Status inquiry
1st byte: Refers to Fan error; one of 0 to 2
2nd byte:
Refers to Light Source error; one of
0 to 2
3rd byte: Refers to Temperature error; one of 0 to 2
4th byte: Refers to Cover error; one of 0 to 2
5th byte: Refers to Filter error; one of 0 to 2
6th byte: Refers to Other error; one of 0 to 2
The meaning of 0 to 2 is as given below
0 = Error is not detected; 1 = Warning; 2 =
Error
LAMP ?
Light Source
Status inquiry
1st number (digits 1 to 5): Light Source Time
2nd number : 0 = Light Source off,
1 = Light Source on
INST ?
Input Source List inquiry
11 12 23 31 33 41 51
NAME ?
Projector Name inquiry Responds with the name set in "PROJECTOR
NAME" of "NETWORK"
INF1 ?
Manufacturer's Name
inquiry
Maxell
INF2 ?
Model Name inquiry
MP-JU4001
MP-JW4001
MP-JW4011
MP-JW3501
MP-JW3511
INFO ?
Other Information inquiry Returns an empty string.
CLSS ?
Class Information inquiry 2
(continued on next page)