2.4.1 Connection diagram
Voltage heating elements 230V.
Any kind of connection: the
safety wire must be connected to
the PE terminal.
Recommended
type of
connection
lead.
1
For 230 V earthed one-phase
connection.
Bridges connect 1 - 2 - 3
terminals and 4 - 5 terminals.
Protective ground to
H05VV-F3G4
2
For 400 / 230 V earthed
two-phase connection.
Bridges connect 2 - 3
terminals and 4 - 5 terminals.
Protective ground to
H05VV-F4G2,5
3
For 400 / 230 V earthed
three-phase connection.
Bridges connect 4 - 5
terminals,
phases
in
succession 1, 2 and 3,
Neutral to 4 - 5.
Protective ground to
H05VV-F5G1,5
L1=R, L2=S, L3=T
N= Earth
PE= earth wire terminal
1.
Check that the technical data of your energy supply meet the values on the
nameplate.
2.
Your domestic circuit must be equipped with an automatic circuit breaker.
3.
Do not attempt to repair the appliance yourself. Repairs carried out by
unauthorized persons can cause serious damage. Always contact the nearest
service centre. Original spare parts should be used only..