33
Adjustment screw
4.
Repeat the adjustment procedure for all burners.
Pressure Testing
1.
Remove left hand pan support and front left burner cap and crown.
2.
Fit manometer tube over the injector.
3.
Turn on the burner gas supply and ignite another burner.
4.
Turn off the burner supplies.
2.8 Conversion from NG to LPG/LPG to NG
DANGER!
The conversion must be carried out by an authorized professional
only!
Check on the appliance which gas category is suitable. The gas supply can be
converted provided that the correct injectors are installed and the gas flow rate is
adjusted properly.
1.
Set all control knobs to OFF (
).
2.
Disconnect the appliance from the electricity supply.
3.
Remove pan supports, burner caps, rings, crowns and control knobs.
4.
The injectors can be replaced by relevant ones using a 7 mm box spanner.
Adjustment of the gas flow rate
With the aid of a thin bladed screwdriver completely tighten down the bypass
adjustment screw, which is located below the centre of the gas tap control shaft.
Upon completion stick the replacement rating plate on the bottom side of the hob.