EL512.256-H Series Operations Manual (020-0354-00A)
8
Installation and Handling
The product should be mounted using the M3 insert nuts on the ECA. Beside
the four corner nuts it is recommended to use also the two center nuts in the
mounting, if the vibration or shock stress is severe.
Before touching the display, necessary precaution must be taken to prevent
application of static charges on the display from the operator or tools.
The display is made of glass material and should be handled with proper care.
Do not drop the display or allow hard objects to strike its surface.
NOTE: For trouble-free data transfer a maximum cable length of 300 mm (12
in.) from data transmitter to display input connector is recommended. If
longer cables up to 2m (80 in.) length are needed, a serial resistor of appr. 47
Ω
could be placed at each of the four signal line outputs of the
transmitter in order to lower signal reflections.
Electrostatic Caution: Planar display use CMOS and power MOS-FET devices.
These components are electrostatic sensitive. Unpack, assemble and examine
this assembly in a staticcontrolled area only. When shipping use packing
materials designed for protection of electrostatic-sensitive components.
Warning:
The product generates potentially dangerous voltages capable
of causing personal injury (high voltage pulses up to 195 Vac). Do not
touch the display electronics during operation!
Fig 3. Video Input Timing.
For ordering information of el512-256-h3-frb and other EL Displays, please visit http://www.eldisplays.com/el512-256-h3-frb/ or call +1-888-394-4998.