Table 4. Video Input Timing. 

Symbol Name 

Min 

Max 

Units 

T1 

Frame time 

8.3 

 --- 

ms 

 

Frame frequency 

 --- 

120 

Hz 

T2 

CP1 High time 

60 

 --- 

ns 

T3 

CP1 Period 

34.5 

 --- 

µs 

 

 

S (FRAME)

CP1 (LINE)

UD0 to UD3
LD0 to LD3

CP2 (SHIFT)

tSU

tHOLD

tF

tR

tS21

tS12

tF

tR

tSU

tHOLD

tS3

tCLK

tCL

tCH

 

Figure 3. Setup and Hold Timing Diagram.

 

 

Table 5. Setup and Hold Timing. 

Symbol Name 

Min. 

Max 

Unit 

tS21 

CP1 allowance from CP2 

 

ns 

tS12 

CP2 allowance from CP1 

200 

 

ns 

tS3 

CP1 allowance to CP2 

50 

 

ns 

tSU Setup 

time 

50 

 

ns 

tHOLD Hold 

time 

40 

  ns 

tR Rise 

time 

 

30 

ns 

tF Fall 

time 

 

30 

ns 

tCLK 

CP2 clock cycle 

154 

 

ns 

tCL 

CP2 clock low time 

60 

 

ns 

tCH 

CP2 clock high time 

60 

 

ns 

Summary of Contents for EL640.480-AF1

Page 1: ...EL640 480 AF1 6 4 Electroluminescent VGA Flat Panel Display USER S MANUAL www planar com...

Page 2: ...Revision Control Date Description July 1997 Document number OM502 00 June 2004 Document number 020 0349 00A...

Page 3: ...cal Characteristics 12 Component Envelope 12 Description of Warranty 13 Ordering Information 13 Support and Service 14 Figures Figure 1 J1 Connector Pinouts 6 Figure 2 Video Input Timing Diagram 7 Fig...

Page 4: ...n and advanced manufacturing technologies Planar s new VGA display family brings the visual performance and image quality of EL into cost sensitive applications that have up to now been limited by the...

Page 5: ...tments and touch screens on the viewing side of the display To this end the glass extends in front of the mounting bezel by approximately 0 5 mm 0 02 It is imperative that any mounting scheme apply un...

Page 6: ...ve to handling When cleaning the edges of the display glass special care should be taken not to damage the leads Cable Length Do not exceed the maximum cable length of 600 mm 24 in Longer cables may c...

Page 7: ...s manual should be met without exception to ensure the long term reliability of the display Planar does not recommend operation of the display outside these specifications Table 1 DC Input Voltage Req...

Page 8: ...and connector configuration are supplied as a single unit from Samtec Consult your Samtec representative 1 800 SAMTEC9 for the cable connector options Table 3 J1 Connector Pinouts Pin Signal Descripti...

Page 9: ...is marked by S scan start up signal as shown in Figure 2 The end of each row of data is marked by CP1 as shown in Figure 2 and Figure 3 Input signals UD0 through UD3 contain the video data for the up...

Page 10: ...CP2 SHIFT tSU tHOLD tF tR tS21 tS12 tF tR tSU tHOLD tS3 tCLK tCL tCH Figure 3 Setup and Hold Timing Diagram Table 5 Setup and Hold Timing Symbol Name Min Max Unit tS21 CP1 allowance from CP2 0 ns tS1...

Page 11: ...e 4 Data Format Self Test Mode The display incorporates a self test mode composed of a 1x2 checkerboard pattern that inverts every few seconds The self test mode is entered by applying power to the di...

Page 12: ...tween every horizontal period The lowest possible frame rate brightness is dependent on the perceived flicker of the displayed image but will most likely be around 60 Hz For more information on scan f...

Page 13: ...se certifications Safety UL544 IEC950 EMI FCC Part 15 J Class B EN55022 Level B Environmental Table 7 Environmental Characteristics Temperature Operating Non Operating Operating Survival 5 to 55 C 40...

Page 14: ...nvelope Figures 5 illustrates the distance components extend behind the display Tall components do not necessarily fill this area Planar reserves the right to relocate components within the constraint...

Page 15: ...shall refund Buyer s paid price for the Goods and have no other liability to Buyer All warranty repairs must be performed at Seller s authorized service center using parts approved by Seller Buyer sh...

Page 16: ...ering support and service are available to make the integration of Planar displays as simple and quick as possible for our customers RMA Procedure For a Returned Material Authorization number please c...

Page 17: ...ope and Asia Pacific Support Olarinluoma 9 P O Box 46 FIN 02201 Espoo Finland Tel 358 9 420 01 Hours M F 7 00am 4pm CET 2004 Planar Systems Inc 06 04 Planar is a registered trademark of Planar Systems...

Reviews: