Page | 10
Planar UltraRes X Series RS232 User Manual
020-1397-00B
Setting
Command Code
Num
e
ric
Com
m
a
nd
Co
de
O
pe
rato
rs
Modifiers
O
pe
ran
ds
Ava
il
a
bl
e
i
n
Sta
nd
by
Example
Notes
Advanced
Color
CMS
211
=?+-
Mod 1: Zone
0 = ZONE.1
1 = ZONE.2
2 = ZONE.3
3 = ZONE.4
255 = CURRENT
Mod 2: Gamut
0 = REC709
1 = SMPTEC
2 = EBU
5 = USER
6 = AUTO
255 = CURRENT
Mod 3: Color Point
0 = RED.X
1 = RED.Y
2 = GREEN.X
3 = GREEN.Y
4 = BLUE.X
5 = BLUE.Y
6 = CYAN.X
7 = CYAN.Y
8 = MAGENTA.X
9 = MAGENTA.Y
10 = YELLOW.X
11 = YELLOW.Y
12 = WHITE.X
13 = WHITE.Y
[None = Set all 14
values at once]
0-800
No
[Set REC709 red x color point in
Zone 1 to 0.640]
CMS(ZONE.1, REC709,
RED.X)=640
CMS(ZONE.1 REC709 RED.X):640
[Set all color points in the User
gamut for Zone 2]
CMS(ZONE.2, USER)=640 330 300
600 150 060 225 329 321 154 419
505 313 329
CMS(ZONE.2 USER):640 330 300
600 150 060 225 329 321 154 419
505 313 329
See Main -> Advanced
Settings -> Advanced
Color.
Note that the color point
values for the Auto gamut
cannot be written. When
read, it returns the values
for the auto-detected
gamut.