36
Planar UltraRes X Series RS232 User Manual
020-1397-00B
Page | 36
Setting
Command Code
Num
e
ric
Com
m
a
nd
Co
de
O
pe
rato
rs
Modifiers
O
pe
ran
ds
Ava
il
a
bl
e
i
n
Sta
nd
by
Example
Notes
Preset
Name
PRESET.NAME
2003 =?
Preset Number
1-1000
String
Yes
[Set Preset 4 name to "Hello"]
PRESET.NAME(4)="Hello"
PRESET.NAME(4):"Hello
"
Sets the name listed for
the preset in the Delete,
Recall and Save menus.
Default = "Preset n",
where 'n' is the preset
number (e.g. "Preset 4")
Preset
Recall
PRESET.RECALL 2001 !
Preset Number
1-1000
No
[Save to Preset 4]
PRESET.RECALL(4)
PRESET.RECALL(4)@ACK
See Main -> Presets ->
Recall.
Preset
Save
PRESET.SAVE
2002 !
Preset Number
1-1000
No
[Save to Preset 4]
PRESET.SAVE(4)
PRESET.SAVE(4)@ACK
See Main -> Presets ->
Save.
A maximum of 100
presets may be saved.
The preset numbers used
do not have to be
contiguous and may be
greater than 100.
Reboot
SYSTEM.
REBOOT
2402 !
No
SYSTEM.REBOOT
SYSTEM.REBOOT@ACK
Forces the system to
restart.
Revert
Image
Settings
REVERT.IMAGE.
SETTINGS
215
!
Zone
0 = ZONE.1
1 = ZONE.2
2 = ZONE.3
3 = ZONE.4
255 = CURRENT
[None = CURRENT]
No
[For Zone 1]
REVERT.IMAGE.SETTINGS(ZONE.
1)
REVERT.IMAGE.SETTINGS(ZONE.
1)@ACK
[For the current zone]
REVERT.IMAGE.SETTINGS
REVERT.IMAGE.SETTINGS@ACK
See Main -> Image Adjust
-> Revert to Defaults.