Table 5.2 - ES- 10024B Test Parameters
Table 5.3 - ES- 6024D Test Parameters
Table 5.4 - ES-14024B Test Parameters
Order of Tests
Output Voltage
Min. Output Amps Max Alternator RPM
Test #1
28.0 ± .5
100
8000
Test #2
28.0 ± .5
65
4000
Test #3
28.0 ± .5
10
2500
Table 5.1 - ES- 10024 & ALV-9610 Test Parameters
Order of Tests
Output Voltage
Min. Output Amps Max Alternator RPM
Test #1
28.0 ± .5
100
8000
Test #2
28.0 ± .5
65
4000
Test #3
28.0 ± .5
10
2500
Order of Tests
Output Voltage
Min. Output Amps Max Alternator RPM
Test #1
28.0 ± .5
65
8000
Test #2
28.0 ± .5
54
4000
Test #3
28.0 ± .5
27
2500
Order of Tests
Output Voltage
Min. Output Amps Max Alternator RPM
Test #1
28.0 ± .5
140
7500
Test #2
28.0 ± .5
83
4000
Test #3
28.0 ± .5
33
3000
Aircraft Alternator
Maintenance Manual
24-30-01
ES1031
Page: 5-6 Rev.
B: 20 Apr. 2022
© 2022 - Hartzell Engine Technologies - All rights reserved