4.0     INSTALLATION:

The Planet Model ULED arm is designed to be mounted above the immediate work area. Standard mounting fixtures for

Planet Model ULED are: Ceiling Mount & Wall Mount (specialised mountings are available on application). In all cases the

suggested mounting height (measured at swivel head) is two metres from floor level. (refer  Fig 1)

To ensure correct balance of the Model ULED movement the lamp must be mounted with the stem, around which it 

rotates, vertical at all times.

(refer  Fig 1)

  WARNING

  The qualified electrician who is responsible for the installation of the ULED must include an isolation switch

(all -pole disconnection) in the fixed wiring of the ULED and a cable tie near the terminal block of the primary (240V) 

wiring (Phase and Neutral) to secure the cables.

Figures 2 - 4 Refers to wall mount options, Figures 6 - 8 Refers to ceiling mount options, Figures 9 - 11 Refers to maintenance 

procedures 

5.0   WALL MOUNT: 

  

WARNING 

  

Ensure before commencing the installation, that the MAINS power circuit is isolated (off).

CHECK AND ENSURE THE FOLLOWING BEFORE COMMENCING INSTALLATION:

•    You have the appropriate mounting template.

•    You have appropriate tools for the job.

•    Confirmed mains cable entry is located appropriately. 

•    The mounting structure is suitable. 

•   

The structural loadings and approx product weights (refer Fig12) 

•    You have appropriate fixing attachments. e.g. Dyna bolts, large screws 

5.1.0   Using appropriate wall template (template 1) mark mounting holes and mains cable entry. Make sure the bottom of 

the template wall mount is 2055mm from the floor to maintain 2000mm clearance at the bottom of the swivel. (ref Fig 1)

5.2.0    Drill 4 mounting holes as shown on template 1.

Fig: 2

Classification: Non invasive med-

ical device, as per label/s below.

Summary of Contents for ULED Series

Page 1: ...with the instructions contained in this service leaflet this product will provide many years of trouble free opera tion Should you have any enquiry comment or special lighting need we would like to hear from you We back our products with pride service and a five year warranty 2 1 0 Environmental Considerations 2 1 1 Standard Packaging I box containing a complete ULED lamp with Installation and use...

Page 2: ...ables Figures 2 4 Refers to wall mount options Figures 6 8 Refers to ceiling mount options Figures 9 11 Refers to maintenance procedures 5 0 WALL MOUNT WARNING Ensure before commencing the installation that the MAINS power circuit is isolated off CHECK AND ENSURE THE FOLLOWING BEFORE COMMENCING INSTALLATION You have the appropriate mounting template You have appropriate tools for the job Confirmed...

Page 3: ...the top 10 attach swivel with bolt and dome nut and tighten 11 ref Fig 3 When attaching the swivel to the bottom spigot ensure the spigot does not slide up into the tube 5 5 5 Feed cable through grommet 12 and slide into position trim cable to suitable length 13 5 5 6 Attach to the appropriate locations on the terminal block 14 ref Fig 4 5 5 7 Replace end cap 15 and cover 16 and screw nut 17 down ...

Page 4: ...Trim and strip wires to appropriate length refer 7 9 Electrical connections 7 8 0 Remove plastic side cover and screw 10 from continuous rotation device Slide push cable from the light head through tube 11 and out the side cover of the continuous rotation device 12 Ensure the grommet 13 is located correctly Trim and strip wires to appropriate length Attach swivel with bolt and dome nut and tighten...

Page 5: ...1 7 7a 8 11 14 14 4 5 6 21 2 20 18 Fig 6 Fig 7 NOTE This section only applies if continuous rotation attachment is fitted 3 9 10 12 13 19 Fig 8 UTW TWIN CEILING MOUNT ...

Page 6: ...refer Fig 9 To prevent undue stiffness or joint seizure the springs of the Planet Model U have been pre packed with high quality grease The pivoting mechanisms at the main elbow joint and the link pin at the swivel head should receive regular light oiling 9 4 Lock Nut Adjustment refer Fig 9 Fine adjustment of the frictional inertia of the lamp movement is provided by tensioning the small lock nut ...

Page 7: ...ig 10 Fig 11 Depress button to remove or replace light head Lock Nut left hand heavy spring tube Spring tension nut WARNING UNDER NO CIRCUMSTANCES SHOULD THE SPRING TENSION NUTS TWO BE COMPLETELY UNDONE ...

Page 8: ...o bottom of swivel head Ensure level Ensure level Recommended height 2055 mm to bottom of mounting plate 610 NOM 16 Nm 445 NOM 12 Nm RELATIVEVERTICAL MASS 2 7kg POSITION SHOWN HERE IS ESTIMATE ONLY ARM HEAD ON LY Note For the purposes of quoting minimum structural requirements of mountings torque load of 12 Newton Metres plus lever arm effect of length of ceiling mount tube or wall mounting must b...

Reviews: