background image

 

WARNING 

 

Take care to remove any dust during the drilling and make sure not to damage any existing cabling

5.4.0   Remove cover from the wall mount  (ref Fig 2) 

1

 , feed mains cable through the larger bottom hole 

2

, place correct 

             wall mount into position and attach to wall using appropriate fixture devices 

3

5.5.0    Electrical Connections
5.5.1   Connect mains cable to appropriate locations on terminal block (ref Fig 2) 

4

5.5.2   Connect the Earth (yellow/Green) cable to the Earth Lug (ref Fig 2) 

5

 

WARNING   

Replace cover ensuring the cables do not get caught/pinched and attach with the screws located at the bottom and top 

6

 

(ref Fig 3)
5.5.3   Remove dome nut  

7

 top cover 

8

 end cap 

9

 (ref Fig 3) 

5.5.4   Slide (push) cable from the light head through tube and out the top 

10

, attach swivel with bolt and dome nut and 

              tighten 

11

.(ref Fig 3) When attaching the swivel to the bottom spigot ensure the spigot does not slide up into the tube 

5.5.5   Feed cable through grommet 

12

 and slide into position, trim cable to suitable length 

13

5.5.6   Attach to the appropriate locations on the terminal block.

14

 (ref Fig 4)

5.5.7   Replace end cap 

15

 and cover 

16

 and screw nut 

17

 down to lock cover in position. (ref Fig 4)

6.0     FINAL INSPECTION, PLEASE ENSURE

6.1.0   The mount is firm and has no movement, and is level (ref Fig1)

6.2.0    The light head moves through its full range of movements 

6.3.0    The assembly of light and mount is clean and free of any marks

6.4.0    Energise circuit and test the light fixture for normal operation, that is the green led on the power supply cover is 
              working 

18

 and the switch on the light head is working (ref Fig 10)

- NEGA TIVE

BL ACK

+ POSITIVE

RED

6

11

14

15

16

18

17

11

6

6

7

8

13

9

10

12

10

Fig: 3

Fig: 4

Summary of Contents for ULED Series

Page 1: ...with the instructions contained in this service leaflet this product will provide many years of trouble free opera tion Should you have any enquiry comment or special lighting need we would like to hear from you We back our products with pride service and a five year warranty 2 1 0 Environmental Considerations 2 1 1 Standard Packaging I box containing a complete ULED lamp with Installation and use...

Page 2: ...ables Figures 2 4 Refers to wall mount options Figures 6 8 Refers to ceiling mount options Figures 9 11 Refers to maintenance procedures 5 0 WALL MOUNT WARNING Ensure before commencing the installation that the MAINS power circuit is isolated off CHECK AND ENSURE THE FOLLOWING BEFORE COMMENCING INSTALLATION You have the appropriate mounting template You have appropriate tools for the job Confirmed...

Page 3: ...the top 10 attach swivel with bolt and dome nut and tighten 11 ref Fig 3 When attaching the swivel to the bottom spigot ensure the spigot does not slide up into the tube 5 5 5 Feed cable through grommet 12 and slide into position trim cable to suitable length 13 5 5 6 Attach to the appropriate locations on the terminal block 14 ref Fig 4 5 5 7 Replace end cap 15 and cover 16 and screw nut 17 down ...

Page 4: ...Trim and strip wires to appropriate length refer 7 9 Electrical connections 7 8 0 Remove plastic side cover and screw 10 from continuous rotation device Slide push cable from the light head through tube 11 and out the side cover of the continuous rotation device 12 Ensure the grommet 13 is located correctly Trim and strip wires to appropriate length Attach swivel with bolt and dome nut and tighten...

Page 5: ...1 7 7a 8 11 14 14 4 5 6 21 2 20 18 Fig 6 Fig 7 NOTE This section only applies if continuous rotation attachment is fitted 3 9 10 12 13 19 Fig 8 UTW TWIN CEILING MOUNT ...

Page 6: ...refer Fig 9 To prevent undue stiffness or joint seizure the springs of the Planet Model U have been pre packed with high quality grease The pivoting mechanisms at the main elbow joint and the link pin at the swivel head should receive regular light oiling 9 4 Lock Nut Adjustment refer Fig 9 Fine adjustment of the frictional inertia of the lamp movement is provided by tensioning the small lock nut ...

Page 7: ...ig 10 Fig 11 Depress button to remove or replace light head Lock Nut left hand heavy spring tube Spring tension nut WARNING UNDER NO CIRCUMSTANCES SHOULD THE SPRING TENSION NUTS TWO BE COMPLETELY UNDONE ...

Page 8: ...o bottom of swivel head Ensure level Ensure level Recommended height 2055 mm to bottom of mounting plate 610 NOM 16 Nm 445 NOM 12 Nm RELATIVEVERTICAL MASS 2 7kg POSITION SHOWN HERE IS ESTIMATE ONLY ARM HEAD ON LY Note For the purposes of quoting minimum structural requirements of mountings torque load of 12 Newton Metres plus lever arm effect of length of ceiling mount tube or wall mounting must b...