5 Mega-pixel Vandalproof IR PoE IP Camera
ICA-E5550V
40
authentication failure. The manager will get the information immediately and take action if
necessary.
Cold start
means device reboot by power disconnection.
Warm start
means device reboot by
firmware without power disconnection. If there other parties attempt to connect to the device
with wrong security password under SNMP v1, v2 or v3 setting, the device will send an
authentication failure
message to the management server.
To enable SNMP Trap function in the camera, type the IP address of the computer running the
SNMP management software and type trap community as password to allow server to get trap
message from device (Default is public). Select available traps and click “
Apply
”.
Camera’s SNMP offers the following information:
Group
Description
System
Provides general information about the managed device.
For example, system description and system name.
Interface
Provides general information from the physical interfaces.
For example, interface speed and MAC address.
Address
Translation
Provides information about the mapping between network addresses and
physical addresses for each physical interface.
For example, the IP/MAC addresses are to connect to the managed device.
IP
Provides the status and operation of Network Layer (Layer 3).
For example, the information and traffic flow of received/delivered package.
ICMP
Provides the status and statistics of ICMP.
For example, amount of receive/error message of ICMP.
TCP
Provides the status and operation of Transport Layer (Layer 4) using TCP
protocol.
For example, TCP Local Port and incoming/outgoing TCP segments.
UDP
Provides the status and operation of Transport Layer (Layer 4) using UDP
protocol.
For example, UDP Local Port and in/out datagram.
SNMP
Provides the related statistics through SNMP
3.7.6 RTP
The
RTP
section allows user to configure RTP Settings.
If the
RTSP Authentication
is “
Enabled
”, then the RTP streaming will require account name
and password authentication.
If the
RTP B2 Frame
is “
Enabled
” then the B2 frame is added to every video frame, containing
additional information, such as
motion detection status on each frame, digital input and
digital output levels, passive infrared status, other video intelligence data, frame
counter, frame-rate mode and the frame-rate, bitrate, resolution, timestamp and much
more
. The user side can operate with video data easily, including event management, storage
consumption estimation, image resizing for preview, etc.
After changing any of the items above, press
Apply
to save the changes. The
Reset
button
undoes the changes that had just been made but not Applied yet.