User’s manual
66
8.8 Alarm
This camera has 8 sensor inputs and two relay outputs (toggle) for event
management.
The alarm inputs can work with positive or negative-trigger source,
with auto-detection. All the inputs are checked by software at
power-on and monitored. If input status is reversed
(i.e. changing
from positive to negative or vise-versa)
, then event will be considered
as is taking place.
important:
To make the event detection (sensor) work properly with this PTZ
camera, keep both of the camera and sensor in POWER-OFF mode
until the wiring work is completed;
Also, power the sensors on before PTZ camera is switched on
If you did not follow the procedure on above, at the final movement,
switch the PTZ camera off and on again to correct the initial status.
Controlled by the residential
software, the camera can be
managed for surveillance and
producing alarm at
event-triggering given by the
alarm inputs.
You will see the menu on screen,
in which there are two parts are to
be arranged:
ALARM
RELAY / OUTPUT
INPUT 1
PRESET 17
INPUT 2
PRESET 18
INPUT 3
PRESET 19
INPUT 4
PRESET 20
INPUT 5
PRESET 21
INPUT 6
PRESET 22
INPUT 7
PRESET 23
INPUT 8
PRESET 24
RETURN
Summary of Contents for CAM-ISD52