2.2 Physical Details
Identification of ICA-312 cables
RS-485 & DI/DO:
Connect RS-485 to external scanner and connect to sensor in
and alarm out devices.
Cable for I/O connectors:
Name Cable
Color Function
12VDC
Gray
DC 12V (50mA maximum)
GND Light
purple GND
D+
Yellow
RS485 data +
D-
Orange
RS485 data -
DI
Stripe purple
Digital signal input
DO
Dark purple
Digital signal output
NOTE:
The RS-485 of ICA-312 is master that can control
external scanner.
Local Video output (BNC port):
The Network Camera also provides composite video output.
User can use BNC video cable to connect the Network
Camera with a TV monitor or VCR.
DC-in Jack:
The input power is 12VDC. Note that supply the power to the
Network Camera with standard power adapter included in
package. Otherwise, the improper power adapter may
damage the unit and result in danger.
RJ45 LAN socket:
Connect to PC or Hub/Switch. For connect to 10Base-T
Ethernet or 100Base-TX Fast Ethernet cabling. This Ethernet
port built N-Way protocol can detect or negotiate the
transmission speed of the network automatically. Please use
Category 5 “straight through” cable to connect the ICA-312 to
a 100Mbps Fast Ethernet network switch or hub.
8