Forgot the IP address of
the ICA-500.
Check IP address of ICA-500 by using the IP Finder program.
IP Finder program
cannot find ICA-500.
•
Re power the ICA-500 if cannot find the unit within 1
minutes.
•
Do not connect ICA-500 over a router. IP Finder program
cannot detect ICA-500.
•
If IP address is not assigned to the PC which running IP
Finder program, and then IP Finder program cannot find
ICA-500. Make sure that IP address is assigned to the PC
properly.
•
Antivirus software on the PC might interfere with the setup
program. Disable the firewall of the antivirus software during
setting up ICA-500.
Internet Explorer does
not seem to work well
with the ICA-500
Make sure that your Internet Explorer is version 6.0 or later. If
you are experiencing problems, try upgrading to the latest
version of Microsoft
’
s Internet Explorer from the Microsoft
webpage at: http://www.microsoft.com/windows/ie.
IP Finder program fails
to save the network
parameters.
•
Don
’
t leave any space in the name field. Use underline,
“
_
”
,
or dash,
“
-
“
to replace the space,
“
“
.
•
Network may have trouble. Confirm the parameters and
connections of the ICA-500.
Access ICA-500
Cannot access the login
page and other web
pages of ICA-500 from
Internet Explorer
•
Another device or computer is already using Maybe the IP
Address of the ICA-500. To confirm this possible problem,
disconnect the ICA-500 from the network first, and then run
the PING utility to check it out.
•
Maybe due to the network cable. Try correcting your
network cable and configuration. Test the network interface
by connecting a local computer to the ICA-500 via a
crossover cable.
•
Make sure the Internet connection and setting is ok.
•
Make sure enter the IP address of Internet Explorer is
correct. If ICA-500 has a dynamic address, it may have
changed since you last checked it.
•
Network congestion may prevent the web page appearing
quickly. Wait for a while.
The IP address and Subnet Mask of the PC and ICA-500
must be in the same class of the private IP address on the
LAN.
•
Make sure the http port used by the ICA-500, default=80, is
forward to the ICA-500
’
s private IP address.
•
The port number assigned in your ICA-500 might not be
available via Internet. Check your ISP for available port.
•
The proxy server may prevent you from connecting directly
to ICA-500, set up not to use the proxy server.
•
Confirm that Default Gateway address is correct.
•
The router needs Port Forwarding feature. Refer to your
router's manual for details.