3. Wiring the Power Inputs
The Upper Panel of the
Industrial Managed Switch
indicates an inlet power
socket and consists of one green terminal block connector with 6 contacts.
Please follow the steps below to insert the power wire.
1. Insert positive/negative DC power wires into Contacts 1 and 2 for Power 1,
or Contacts 5 and 6 for Power 2.
DC 9-48V, AC 24V
Max. Fault Alarm Loading: 24V, 1A
DI1 DO0 DO1
DI0
GND
GND
V1+
V2+
PWR1
PWR2
Alarm
DC Input: 9-48V , 4A max.
AC Input: 24V , 2A max.
1 2 3 4 5 6
1 2 3 4 5 6
Figure 3-1:
IGS-6325-5X1T Upper Panel
Refer to the table below for the Input Voltage and Current values for each
model.
IGS-6325-4T2X
IGS-6325-5X1T
DC Input Voltage
9-48VDC
9-48VDC
DC Max. Input Current
3A
4A
AC Input Voltage
24VAC
24VAC
AC Max. Input Current
1.5A
2A
PWR1 and PWR2 must provide exactly the same DC voltage for
power load balance while operating with dual power input.