background image

18

FCC Statement

NOTE: This equipment has been tested and found to comply with the 
limits for a Class A digital device, pursuant to part 15 of the FCC Rules. 
These limits are designed to provide reasonable protection against 
harmful interference when the equipment is operated in a commercial 
environment. This equipment generates, uses, and can radiate radio 
frequency energy and, if not installed and used in accordance with 
the instruction manual, may cause harmful interference to radio 
communications. Operation of this equipment in a residential area 
is likely to cause harmful interference in which case the user will be 
required to correct the interference at his own expense.

ISEDC Statement

CAN ICES-003(A) / NMB-003(A)
This device complies with Industry Canada license-exempt RSS 
standard(s).
Operation is subject to the following two conditions: (1) this device 
may not cause interference,

 

and (2) this device must accept any 

interference, including interference that may cause undesired

 

operation 

of the device.
Le present appareil est conforme aux CNR d'Industrie Canada 
applicables aux appareils radio

 

exempts de licence. L'exploitation est 

autorisee aux deux conditions suivantes: (1) l'appareil ne

 

doit pas 

produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout 
brouillage

 

radioelectrique subi, meme si le brouillage est susceptible 

d'en compromettre le fonctionnement.

CE Mark Warning

This device is compliant with Class A of CISPR 32. In a residential 
environment this equipment may cause radio interference.

Summary of Contents for IPOE-171-60W

Page 1: ...Industrial 802 3bt Multi Gigabit PoE Injector IPOE 171 60W IPOE 171 95W User s Manual ...

Page 2: ... 3 Wiring the Power Inputs 10 3 4 Wiring the Fault Alarm Contact 12 4 Mounting Installation 13 4 1 DIN rail Mounting Installation 13 4 2 Wall mount Plate Mounting 13 4 3 Side Wall mount Plate Mounting 14 4 4 Grounding the Device 14 5 Hardware Installation 15 5 1 Before Installation 15 5 2 IPOE 171 60W IPOE 171 95W Installation 15 6 Customer Support 17 ...

Page 3: ...peed PoE Standard PoE Budget IPOE 171 60W 10M 100M 1G 2 5G 5Gbps IEEE 802 3at bt 60 watts IPOE 171 95W 10M 100M 1G 2 5G 5Gbps IEEE 802 3at bt 95 watts Please unpack the box of the device carefully and the box should contain the following items 802 3bt PoE injector x 1 User s manual x 1 Dust cap x 2 Wall mount kit x 1 If any item is found missing or damaged please contact your local reseller for re...

Page 4: ...X 4 pair UTP Cat 5 5e 6 6A 1G 2 5G 4 pair UTP Cat 5e 6 6A 5G 4 pair UTP Cat 6 6A LED Indicators System Power 1 Green Power 2 Green Alarm Red PoE Port PoE in Use x 1 Amber PoE Usage PoE Usage x 3 Amber Data Rate 10M 100M 1G 2 5G 5Gbps Dimensions W x D x H 135 x 87 8 x 32 mm ESD Protection 6KV DC Enclosure Metal case Weight 406g 443g Power Requirements DC 48 54V 2A max DC 12 54V 6A max Unit Output V...

Page 5: ...0 watt PoE via 2 pair PoE Power Output Max 60W 1m cable Max 51W 100m cable DC 24V 48V input Max 89 5W 1m cable Max 75W 100m cable DC 12V input Max 60W 1m cable Max 52W 100m cable PoE Power Supply Type End span Mid span Power Pin Assignment Pair 1 End span 1 2 3 6 Pair 2 Mid span 4 5 7 8 PoE Mode Standard mode Legacy and Force mode Standards Conformance Standards Compliance IEEE 802 3 10BASE T Ethe...

Page 6: ...ees C Operating Humidity 5 90 relative humidity non condensing Storage Humidity 5 90 relative humidity non condensing Caution 1 As IEEE 802 3bt device provides high power please use high quality network cable and RJ45 connector 2 The maximum PoE output power depends on the cable length the quality of cable and DC input voltage ...

Page 7: ...PoE Power Usage PoE in Use Standard Legacy 10 100 1G 2 5G 5G Ethernet 10 100 1G 2 5G 5G Ethernet DC P1 P2 Alarm IPOE 171 95W 802 3bt PoE Figure 1 IPOE 171 60W outlook Figure 2 IPOE 171 95W outlook IPOE 171 60W LED Indicators LED Color Function P1 Green Lights to indicate power 1 has power P2 Green Lights to indicate power 2 has power Alarm Red Lights to indicate either power 1 or power 2 has no po...

Page 8: ...than 9W 2 Blinks to indicate that the PoE usage is around 10W to 19W 3 Lights to indicate the PoE usage is more than 20W 40W 1 Blinks to indicate that the PoE usage is around 30W to 39W 2 Lights to indicate the PoE usage is more than 40W 60W 1 Blinks to indicate that the PoE usage is around 50W to 59W 2 Lights to indicate the PoE usage is at the maximum IPOE 171 95W LED Indicators LED Color Functi...

Page 9: ... standard mode is chosen to provide power to the PD devices that follow the IEEE 802 3at bt standard Legacy The legacy mode supports Ultra PoE It is chosen to provide power to the PD devices that do not fully follow the IEEE 802 3at bt standard Force Warning If the output power of injector is less than 1 watt when in the Legacy mode after 20 seconds the Force mode will be enabled When the Force mo...

Page 10: ...larm Loading 24V 1A V1 V2 PWR1 PWR2 Alarm 1 2 3 4 5 6 Figure 4 IPOE 171 95W upper panel 3 3 Wiring the Power Inputs The 6 contact terminal block connector on the top panel of the IPOE 171 series is used for two DC redundant power inputs Please follow the steps below to insert the power wire Step 1 Insert Positive Negative DC power wires into Contacts 1 and 2 for POWER 1 or 5 and 6 for POWER 2 DC I...

Page 11: ...Alarm Power 2 Figure 6 PWR1 PWR2 Pins of Terminal Block Note 1 The wire gauge for the terminal block should be in the range between 12 24 AWG 2 As the DC input connector of the IPOE 171 series is polarity protected connecting Positive Negative DC power wires to the wrong pins will not damage the unit ...

Page 12: ...form an open circuit The following illustration shows an application example for wiring the fault alarm contacts Figure 7 Fault Pin of Terminal Block Note 1 The wire gauge for the terminal block should be in the range between 12 24 AWG 2 Alarm relay circuit accepts up to 24V max 1A currents Fault Alarm Contacts The Fault Alarm Contacts are energized CLOSE for normal operation and will OPEN when fa...

Page 13: ...tions and perform the procedures in the order being presented Note In the installation steps below this manual uses PLANET Industrial Switch as an example The steps for PLANET Industrial Slim type Switch Industrial Media Serial Converter and Industrial PoE devices are similar 4 1 DIN rail Mounting Installation 1 2 4 2 Wall mount Plate Mounting ...

Page 14: ...r illustration only 4 4 Grounding the Device Users MUST complete grounding wired with the device otherwise a sudden lightning could cause fatal damage to the device DC Input 12 54V 6A max Max Fault Alarm Loading 24V 1A V1 V2 PWR1 PWR2 Alarm 1 2 3 4 5 6 Earth Ground ...

Page 15: ...networked device the IPOE 171 series with POE 173S IPOE 173S can supply DC power to this Ethernet device conveniently and easily Note 1 In the installation steps below this manual uses the IPOE 171 60W as an example Except the input voltage the steps for the IPOE 171 95W are similar 2 Note that the input power range of the IPOE 171 60W is 48 54V DC and the input power range of IPOE 171 95W is 12 5...

Page 16: ...ine DC 1000BASE T UTP PoE 1000BASE T UTP with PoE Power Data PoE PTZ IP Camera PoE Power DC Input DC 40 75 Figure 9 Architecture of connected IEEE 802 3at bt device Once the IPOE 171 60W detects the existence of an IEEE 802 3at bt device the PoE in Use LED indicator will be steadily on to show it is providing power Note 1 According to IEEE 802 3at bt Power over Ethernet the IPOE 171 Series will no...

Page 17: ... need more support information please contact PLANET support team PLANET online FAQs https www planet com tw en support faq Support team mail address support planet com tw Copyright PLANET Technology Corp 2022 Contents are subject to revision without prior notice PLANET is a registered trademark of PLANET Technology Corp All other trademarks belong to their respective owners ...

Page 18: ...t his own expense ISEDC Statement CAN ICES 003 A NMB 003 A This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Le present appareil est conforme aux CNR d Industrie Can...

Page 19: ...sult of the presence of hazardous substances in electrical and electronic equipment end users of electrical and electronic equipment should understand the meaning of the crossed out wheeled bin symbol Do not dispose of WEEE as unsorted municipal waste and have to collect such WEEE separately ...

Page 20: ......

Reviews: