background image

Copyright Planika Sp. z o.o.  

www.planikafires.com 

 

IG0266#03 

02.06.2020 

 

18 

8.

 

TECHNICAL SPECIFICATION 

Applianace Category 

I3P 

I3B/P 

I3+ 

I2H/E 

I2L 

Gas type 

  

G31 

G30 

G30 

G31 

G20 

G25 

Gas pressure 

[mbar] 

30 

37 

50 

30 

37 

50 

28-30 

37 

20 

25 

Injector diemater 

[mm] 

2,0 

2,7 

Burner Pressure 

[mbar] 

30 

37 

50 

30 

37 

50 

28-30 

37 

20 

25 

Gas consumption 

[g/h] 

0,84  0,93  1,08  0,84  0,93  1,08  0,80-0,84  0,93 

 

 

 

[m3/h] 

 

 

 

 

 

 

 

 

1,22 

1,37 

Nom. Input (Hi) 

[kW] 

10,6  11,8  13,7  12,1  13,5  15,6  11,7-12,1  11,8 

13,6 

15,3 

Safety device 

Thermocouple 

Gas control valve 

BS190 

Flexible hose (4 m) 

Ø9mm

 

 

 

9.

 

MANUFACTURER’S CONTACT DETAILS

 

Company Name: 

 

Planika Sp. z o.o. 

Address: 

 

 

Bydgoska 38 

 

 

 

 

86-061 Brzoza 

 

 

 

 

Poland 

Telephone:   

 

+ 48 52 364 11 60 

 

 

Summary of Contents for Galio Black

Page 1: ...2 06 2020 1 INSTALLATION and USER S MANUAL Galio Corten Black Manual G20 G25 Natural Gas G30 G31 Propane Butane Propane H H1 H2 L L1 L2 L3 D mm 500 300 200 1140 944 98 98 350 Manufactured by Planika Sp z o o Bydgoska 38 86 061 Brzoza Poland D H H1 H2 L L2 L1 L3 ...

Page 2: ...e only LPG version 7 3 5 Installation of the gas linkage 8 3 5 1 Natural gas connection 8 3 5 2 Connection and replacement of the gas cylinder LPG version 8 3 5 3 Regulator replacement LPG version 11 4 OPERATING INSTRUCTIONS 12 4 1 General Notes 12 4 2 Start up of the device 13 4 3 Regulation of the flame size 14 4 4 Device shutdown 14 5 TESTING 15 5 1 Checking for gas leaks 15 5 2 Checking the fl...

Page 3: ...e placed near the device During the first ignition The Galio Corten Black Manual fireplace needs to be burnt on maximum level for a few hours in order for the elements to acquire correct temperature and for the remains of paint lacquer and lubricant to evaporate Do not move the device while it s working Galio Corten Black Manual has been designed for decorative purposes The surface of The Galio Co...

Page 4: ... not allow an open flame or any ignited object to reach the gas cylinder The gas cylinder should be in a distance not shorter than 1 5 metres away from The Galio Corten Black Manual fireplace Leaks should be found with the use of a cleaning liquid and water If bubbles form on the surface that means that a there s an existing leak Always use a pressure regulator between the gas bottle and the devic...

Page 5: ...the unit Carefully lift the appliance and pull out the glass shield wrapped in cardboard from the inside of the Galio Corten Black Manual Check the completeness of the elements with the contents list Make sure that the device nor its elements weren t damaged during the transportation if they were notify the supplier Place Galio Corten Black Manual on a flat paved surface outside of the building pr...

Page 6: ... the points were completed according to the instruction the gas bottle can be now connected See point 3 5 3 3 Installation of glass screens Carefully remove cardboard and foam foil from the glass screens Remove all contaminations from the glass shields which could burn out on the glass during operation of The Galio Corten Black Manual in particular fingerprints Install glass shields in the corresp...

Page 7: ... optional housing for the gas bottle cannot be airtight and has to be correctly ventilated The housing needs to have an upper ventilation slot above the top of the bottle of an area min 1 100 of the area of the base of the housing and a lower ventilation slot of an area min 1 50 of the area of the base of the housing The dimensions of the housing may vary to accommodate different types and dimensi...

Page 8: ...ns so there is no pressure loss Ball gas valve should be installed in an easily accessible place and have the necessary CE mark 3 5 2 Connection and replacement of the gas cylinder LPG version The Galio Corten Black Manual is delivered together with an elastic gas linkage which on one end is connected to the valve of the device and on the other end to the 37mbar regulator in the twist on version r...

Page 9: ...ing knob left thread Do not allow the gas bottle connectors to be fastened too tightly 3 Place the quick release regulator on the valve and press it down hard If the switch is correctly turned off you will hear a characteristic click 5 When the gas flow is required turn the valve of the bottle counter clockwise 4 To let the gas flow in turn the switch into the ON position or into the flame image P...

Page 10: ...e switch into the OFF position 3 NEVER DO NOT unmount the regulator or connecting nut when the bottle valve is open 4 TAKE OFF the regulator or the connecting nut with the use of a wrench or a connecting knob 3 Take off the quick release regulator by pressing the switch horizontally and simultaneously pulling the whole regulator upwards 5 REPLACE the linkage closer or cap on the empty or partially...

Page 11: ...0 mbar Use only the redactors that comply with the EN16129 European Norm 2 Turn off the Galio Corten Black Manual the OFF position The main burner and the pilot burner need to be turned off 3 Disconnect the regulator from the gas bottle description above 4 Loosen the metal clamp with the use of a screwdriver philips or a flat wrench 5 Move the clamp away from the stub of gas regulator 6 Take off t...

Page 12: ...RUCTIONS 4 1 General Notes The Galio Corten Black Manual fireplace has a control valve with a built in ignition for the main burner without pilot flame The flame height of the main burner may be appropriately regulated with by turning the knob Next to the knob is placed elective ignition button powered by AAA battery The control panel is placed on one of the shorter sides of the base of the firepl...

Page 13: ...position 2 Photo 5 While keeping the knob still pressed start the flame by pressing the ignition button 3 Photo 6 A spark will appear which ignites the main burner on the minimum flame height If the flame did not ignite repeat this process 2 3 times This will be required especially when you have replaced and installed a new LPG gas cylinder When the flame is ignited keep holding the knob for aroun...

Page 14: ...kage In this case conducting a few attempts will be needed until the flame is ignited 4 3 Regulation of the flame size When the flame is burning the desired height of the flame may be adjusted and regulated by turning the knob clockwise or counter clockwise To achieve a higher flame turn the know clockwise to Hi position To achieve a lower flame turn the knob counter clockwise to Lo position Photo...

Page 15: ... into the container WARNING Remember about proper polarization of the battery Screw the cover of the battery container 5 TESTING WARNING NEVER TURN ON THE DEVICE IF THE CHARACTERISTIC SMELL OF GAS IS PERCEPTIBLE If you smell gas during the operation of the fireplace turn off the device immediately and cut off the gas supply from the gas cylinder by shutting its valve 5 1 Checking for gas leaks Che...

Page 16: ...winter period 6 1 Testing and cleaning Please check and clean if necessary The main burner if necessary remove broken parts of stones and the existing dust Pilot burner and thermo couple if necessary remove the existing sediment In the event of visible damage contact your dealer Igniter gap between igniter and pilot flame should not be bigger than 5 mm Glass screens check for dirt smudges or possi...

Page 17: ...ed 7 Pressure regulator link is loose 1 Replace Gas Cylinder 2 Connect the igniter linkage 3 Replace igniter 4 Realign electrode and clear any surrounding debris from area 5 Unmount burner clean the nozzle 6 Straighten the linkage Keep the linkage away from the housing 7 Tighten the link Check for leaks Igniter Not Working 1 Ignitor wire not connected 2 Electrode misaligned on pilot burner 3 Ignit...

Page 18: ...tor diemater mm 2 0 2 7 Burner Pressure mbar 30 37 50 30 37 50 28 30 37 20 25 Gas consumption g h 0 84 0 93 1 08 0 84 0 93 1 08 0 80 0 84 0 93 m3 h 1 22 1 37 Nom Input Hi kW 10 6 11 8 13 7 12 1 13 5 15 6 11 7 12 1 11 8 13 6 15 3 Safety device Thermocouple Gas control valve BS190 Flexible hose 4 m Ø9mm 9 MANUFACTURER S CONTACT DETAILS Company Name Planika Sp z o o Address Bydgoska 38 86 061 Brzoza ...

Reviews: