Copyright Planika Sp. z o.o.
www.planikafires.com
IG0139#02
30.07.2018
34
Connection to the existing chimney (type C91)
The device can also be connected to an existing chimney using for this purpose a flexible stainless steel tube
affixed to the chimney with a diameter corresponding to the diameter of the exhaust outlet of the device for
the purpose of discharging flue gases (130mm). The area around is used to supply air for combustion. Please
note that the system should start from a minimum of 1 m section of the concentric flue system (200/130),
only then connect it to the system inside the existing chimney.
In case of connecting to an existing chimney, the following requirements apply:
Approved only for use in combination with a special chimney set supplied by the manufacturer.
The internal dimension of the existing chimney should be at least 200 x 200 mm, and the vertical height
should be up to 12 meters.
The total length of the horizontal pipe must not exceed a maximum length of 4 m.
The existing chimney should be cleaned and sealed.
In case of installation to the fireplace housing with already existing chimney, the same guidelines and
instructions apply as like in case of the device with concentric system described above.
WARNING!
Installation manual is supplied separately with the supplied system.
Picture 11 – Sample configuration of connecting to an existing chimney