Copyright Planika Sp. z o.o.
www.planikafires.com
IG0139#02
30.07.2018
60
systems. During maintenance work, close the gas valve and make sure that the device is not energized, and
after the review/repair, check the gas tightness of the entire system.
During the audit work, you should also clean all the glass of the device. To do this you have to:
Remove the front glass as described in section 5.12.
Avoid leaving fingerprints and remove them from the surface of the glass, because they burn out
permanently on the glass.
Clean the glasses according to the recommendations contained in the User Manual.
Remove the white layer which is formed after the first period of use.
Replace damaged and/or broken glasses as described in section 5.12.
Warning!!!
Glasses should be cleaned only when they are at room temperature
8.1.
Spare parts
Use only original spare parts, which are available from the supplier.
9.
DELIVERY
After successful installation of the device, the installer is obliged to explain to the user how to operate the
device and give him instructions how to start the device, security measures, use of the remote control and
annual maintenance.
Additionally, the installer must provide the user with the following information and instructions:
In case of perceived irregularities in the operation of the device, immediately close the gas valve and
contact your installer in order to avoid dangerous situations.
Indicate the user to the location of the gas valve.
Pay attention to the preventive measures listed in the User Manual which protect against inadvertent
ignition by other wireless remote controls, such as car keys and remote controls for garage doors.
Pay attention to the fact that the device is connected to 230 V.
Instruct the user on the device and use the remote control.
Issue the user with manual and assembly instructions and advised that all instructions must be kept
near the unit.
Tell the User that is required to read the Safety Instructions contained in the Manual and that all
instructions must be stored for the lifetime of the device.
When the device is put into operation, it must be pointed out that:
o
When the unit is lit for the first time, it comes to the evaporation of volatile components from
paint, materials, etc. and during the volatilization of these substances, the device should work
with the highest heat load.
o
The room should be well ventilated.