14
TROUBLESHOOTING
Some alarms are accompanied by a sound signal. Press
START/STOP
to mute.
Lp.
DIODES
SOLUTION
(contact the Service Department if the solution does not eliminate the error)
1.
The device is being cooled. Wait for the green diode
.
2.
The device run out of fuel while operating. The device is being cooled.
Wait for the red diode to turn off. Refill the tank.
3.
An internal fuel spill occurred. Disconnect the pump. Wipe the visible liquid and wait
for min. 1 hour. Press and hold
ECO
on the control panel for 10 seconds. If the error is
not eliminated, wait for min. 24 hours.
If the error occurred during flame ignition, it means that the ignition time
has been exceeded. Press and hold
ECO
on the control panel for 10 seconds.
4.
Device error. Press and hold
ECO
on the control panel for 10 seconds.
5.
Tank overfilled. Contact the Service Department.
6.
Room temperature too low (<10
°C)
or device error. Increase the room temperature.
Press and hold
ECO
on the control panel for 10 seconds. Wait for the green diode
.
7.
Device overheat. Please contact service department.
FUEL
-
Use only fuels consisting of
95-96,6%
ethanol by volume. FANOLA
®
is the recommended fuel. Do not use gel,
thick and viscous fuels or fuels of improper electric conductivity. The values must be compliant with those of
FANOLA
®
. Other fuels, such as dehydrated ethanol (i.e. consisting of more than 96,6% by volume ethanol) will cause
a device error and loss of the guarantee.
Fuels consisting of 100% by volume ethanol will damage the device.
CLEANING
–
Clean with a damp cloth and delicate detergents, only when the device is turned off and cooled.
SERVICE
– Keep the provided USB cable for service. Reach out to us at
service@planikafires.com
.
BRENNSTOFFNACHF
ÜLLEN
1.
Ist der Brennstofftank leer (
),
nehmen Sie den Behälter aus dem Schrank heraus (
) (I).
2.
Ersetzen Sie den leeren Behälter durch einen neuen (
) (II).
3.
Schrauben Sie den Verschluss an dem neuen Tankbehälter zu (III).
FLAMMENZÜNDUNG
Die grüne Diode
bedeutet, dass der Kamin betriebsbereit ist.
Drücken Sie
START
für 3 Sekunden. Die Flammenzündung dauert 2-10 Minuten (
). In dieser Zeit kann der Geruch
von Kraftstoffdämpfen zu spüren sein. Die ausgeschaltete Diode
READY
(
)
bedeutet, dass die
Flamme gezündet
wurde und der Kamin die Betriebstemperatur erreicht hat.
I
III
II
D
EU
T
SC
H
Summary of Contents for Scandi
Page 6: ...6 2 1 1 1 2 2 1 1 1 2 3 ...