It is suitable for use in places where buses, trains, coaches, and long-distance buses are prone to
odor and bacteria.
Use and characteristics
Plasma generator
Power and other
indicator signals
are not lit
Check if the power cords securely inserted into the unit and
it is loose. Check the power outlet for power supply and check
the 1.0 mA standard (certified) fuse
Under normal circumstances, there is a slight current sound
and black There is a faint blue light in the dark. If found.The
ion tube bursts and the ion tube needs to be replaced.0.5 mA
standard (with certified) fuse.
Please send the following to the company's designated
maintenance department for repairs.
1. The problem cannot be solved as described above.
2. Foreign matter or moisture enters, and abnormal conditions occur.
Fault condition
Processing check
Fault check
Precautions
This machine is designed for only indoor general using. Do not place it open-air or high
temperature place.
Before operating the machine, make sure the power cord is firmly plugged into the power
outlet, and place the power cord in a safe position. Do not touch, install or unplug the
power cord with wet hands to avoid electric shock accidents.
Before unplugging the power cord, please turn off the machine power in the correct
procedure, otherwise it may cause damage to the machine.
If don't use the machine for a long time, please unplug the power supply.
Before operation, please check whether the air inlet and outlet positions of the machine
are blocked.
Do not put debris at the air inlet or outlet, because there is the fan installed inside with
high-speed rotation, it may caused injured if touch it.
In order to ensure the best performance of the machine, do not place any obstacles within
1 meter nearby of the air outlet position and air introduction position.
The machine has precision components built inside. Don't open the case by yourself to
avoid damage to the machine parts and may happen dangerous.
Do not dismantle the front wind panel or the chassis during machine is operating to avoid
dangerous.
Pay attention to ventilation when using it together with fuel appliances. Please do not use
machine in the kitchen.
Before cleaning the chassis of the machine, make sure turn off the power and unplug it of
the machine.Only use cloth with a little clean water and clean it softly,don't use volatile
cleaners.
Forbidding to place and using in the bathroom, otherwise it may cause electric shock.
There are electronic devices installed inside, do not open the case to avoid the risk of electric shock.
Please read this [user manual] carefully before using the machine and follow the below points of
operation base on the manual.Other wise It may cause damage to product, or even cause injury
to yourself or others at varying degrees.
1.Please read this manual carefully before use.
2.Free services can be provided with warranty card and invoice,welcome to contact us
if you need technical support.
3.Customers can get 1 year warranty service from us with product related invoice and
documents.
4.Please keep the warranty card properly so that the warranty can be obtained when
the product needs repair.
5.The company is not responsible for the following repair services beyond the product,
but we can still provide you with paid services.
Products due to improper use or storage.
Products without warranty card or other valid documents.
Products due to unstable power supply voltage or beyond the normal voltage
range or power supply and installation does not meet the electrical installation
requirements.
Promotional products.
Products damaged caused by irresistible natural disasters.
Products beyond maintenance period,damaged due to not follow the rules and
methods of application.
Maintenance notice
Composition unit
Control panel
DC24V
Air outlet
Air outlet
Air inlet
Safe Lock
Machine
lock
①
②
③
④
①
Fuse
②
Work lights
③
Power switch
④
Power socket
Model
Voltage
Area
Power
Air volume
Weight
Noise
Ion tube
Size
Ion tube size
PS-500T2
DC24V
50
-
100㎡
≤
50dB
500*340*60mm
23W
0-130CFM/0
-
220m³/h
3Kg
2
(
Standard
)
80mm(3inch)
Filter type
Ion tube life
Pre-filter
≤2 years
Technical specification
Plasma ions generator play a long-lasting and active positive and negative ion purification effect.
Shell is metal material
This product can be used for a long-term.(Suggest clean the ion tube about 12 months later,
clean or change the filter)