background image

It is suitable for use in places where buses, trains, coaches, and long-distance buses are prone to 
odor and bacteria.

Use and characteristics

Plasma generator

Power and other
indicator signals 
are not lit

Check if the power cords securely inserted into the unit and 
it is loose. Check the power outlet for power supply and check 
the 1.0 mA standard (certified) fuse

Under normal circumstances, there is a slight current sound 
and black There is a faint blue light in the dark. If found.The
ion tube bursts and the ion tube needs to be replaced.0.5 mA
standard (with certified) fuse.

Please send the following to the company's designated 
maintenance department for repairs.
1. The problem cannot be solved as described above.
2. Foreign matter or moisture enters, and abnormal conditions occur.

Fault condition

Processing check

Fault check

Precautions

This machine is designed for only indoor general using. Do not place it open-air or high 
temperature place.

Before operating the machine, make sure the power cord is firmly plugged into the power

 outlet, and place the power cord in a safe position. Do not touch, install or unplug the 

power cord with wet hands to avoid electric shock accidents.

Before unplugging the power cord, please turn off the machine power in the correct 
procedure, otherwise it may cause damage to the machine.

If don't use the machine for a long time, please unplug the power supply.

Before operation, please check whether the air inlet and outlet positions of the machine

 are blocked.

Do not put debris at the air inlet or outlet, because there is the fan  installed inside with

 high-speed rotation, it may caused injured if touch it.

In order to ensure the best performance of the machine, do not place any obstacles within 
1 meter nearby of the air outlet position and air introduction position.

The machine has precision components built inside. Don't open the case by yourself to 
avoid damage to the machine parts and may happen dangerous.

Do not dismantle the front wind panel or the chassis during machine is operating to avoid

 dangerous.

Pay attention to ventilation when using it together with fuel appliances. Please do not use 
machine in the kitchen.

Before cleaning the chassis of the machine, make sure turn off the power and unplug it of 
the machine.Only use cloth with a little clean water and clean it softly,don't use volatile 
cleaners.

Forbidding to place and using in the bathroom, otherwise it may cause electric shock.

There are electronic devices installed inside, do not open the case to avoid the risk of electric shock.
Please read this [user manual] carefully before using the machine and follow the below points of 
operation base on the manual.Other wise It may cause damage to product, or even cause injury
 to yourself or others at varying degrees.

1.Please read this manual carefully before use.

2.Free services can be provided with warranty card and invoice,welcome to contact us
 if you need technical support.

3.Customers can get 1 year warranty service from us with product related invoice and 
documents.

4.Please keep the warranty card properly so that the warranty can be obtained when 
the product needs repair.

5.The company is not responsible for the following repair services beyond the product, 
but we can still provide you with paid services.

Products due to improper use or storage.

Products without warranty card or other valid documents.

Products due to unstable power supply voltage or beyond the normal voltage 
range or power supply and installation does not meet the electrical installation 
requirements. 

Promotional products.

Products damaged caused by irresistible natural disasters.

Products beyond maintenance period,damaged due to not follow the rules and 
methods of application.  

Maintenance  notice

Composition  unit

Control panel

DC24V

Air outlet

Air outlet

Air inlet

Safe Lock

Machine
lock

Fuse

Work lights

Power switch

Power socket

Model

Voltage

Area

Power

Air volume

Weight

Noise

Ion tube

Size

Ion tube size

PS-500T2

DC24V

50

-

100㎡

50dB

500*340*60mm

23W

0-130CFM/0

-

220m³/h

3Kg

2

Standard

80mm(3inch)

Filter type

Ion tube life

Pre-filter

≤2 years

 Technical  specification

Plasma ions generator play a long-lasting and active positive and negative ion purification effect.

Shell is metal material

This product can be used for a long-term.(Suggest clean the ion tube about 12 months later,
clean or change the filter)

Reviews: