Congratulations on the purchase of your PlasmaMade Air Cleaner! Carefully 

remove the packaging material and ensure environmentally friendly disposal 

of the packaging material. Check the product for damage and whether the 

specified parts are present (in case of damage or missing parts, contact your 

point of sale).

•  Product manual.

•  PlasmaMade Air Cleaner TAC120.

•  HEPA / Carbon filter 

    (filter present in Air Cleaner)

•  5v Adapter with  1m USB-C cable.

The Air Cleaner is only intended for indoor use and should not get wet. Only use the supplied adapter to connect the 

product. Check whether the mains voltage corresponds to the voltage of the adapter. The Air Cleaner can be used by 

children aged from 8 years and above and individuals with reduced physical, sensory or mental capabilities or lack of 

experience and knowledge, if they are supervised or have been instructed in the use of the product and are aware of 

the hazards involved. Children are not allowed to play with the Air Cleaner. Children must not perform maintenance or 

cleaning of the product. Do not block the air inlet and outlet of the Air Cleaner. Do not place any objects on top of the Air 

Cleaner. Always remove the plug from the socket when replacing the filter, moving or cleaning the Air Cleaner. When 

removing the plug, do not pull the cable. The Air Cleaner is not a substitute for ventilation or the use of an extractor hood. 

The Air Cleaner is only intended for consumer use under normal conditions of use. Do not attempt to repair, disassemble 

or modify the Air Cleaner yourself. Do not use the Air Cleaner in an environment with high humidity or high ambient 

temperature. Never use the Air Cleaner without a filter. Keep your proof of purchase.

Pay attention

1.

Safety

Do not clean the Air Cleaner with water, (flammable) cleaning agents or other liquids. 

Do not spray flammable materials (such as insecticides or perfume) in or around the 

product. Do not handle the Air Cleaner, cable or adapter with wet hands. Do not insert objects or fingers into 

the inlet or outlet of the Air Cleaner. Do not use the Air Cleaner if the cord, adapter, socket or the product itself is 

damaged. If the Air Cleaner makes unusual noises, produces smoke or a burnt smell, remove the plug from the 

socket immediately. Always remove the plug from the socket and the product before the filter is removed, do not 

reinsert the plugs until a filter is present in the product.

Warning

The PlasmaMade Air Cleaner TAC120 cleans the air from impurities and creates a bubble of clean air around the 

user. For the most effective air cleaning, place the Air Cleaner elevated and close to the user such as on a table or 

desk. The Air Cleaner is most effective in rooms up to 10m2. The Air Cleaner is equipped with a HEPA/Carbon filter 

that filters fine dust, smells, mold spores, allergens and other solid substances. Keep a minimum of 5 cm around 

the Air Cleaner free of obstacles and do not block the air inlet and outlet. The filter of the Air Cleaner becomes full of 

contaminants over time and should be replaced at least every 6 months. For information on replacing the filter see 

chapter 3.

Using the Air Cleaner

The Air Cleaner is equipped with a sensor that measures 

the concentration of VOC (volatile organic compounds) 

in the air and determines the air quality with that 

information. In automatic mode, the fan is controlled 

depending on the measured air quality. The measured air 

quality can be read from the color of the LEDs.

Air quality sensor

Fan speed

Normal

Normal

Fast

Air quality 

Good

Normal

Bad

LED color

Green

Light blue

Red

Always remove the plug from the socket before performing any maintenance on the 

Air Cleaner. We recommend vacuuming the filter monthly and replacing it every 6 

months. The life of a filter strongly depends on how much the Air Cleaner is used and 

the amount of pollution in the air. Follow the instruction pictures on the back of this 

manual to replace the filter. Use a dry microfibre cloth to wipe and clean the Air Cleaner. Do not use 

(flammable) liquids.

3.

Filter replacement and cleaning

6.

Service

The PlasmaMade Air Cleaner TAC120 has a two year warranty, this warranty applies to the electronic part of the 

product and assumes that the manual has been followed correctly and that the product has been used under normal 

conditions. For any problems please contact service@plasmamade.com

Air Cleaner does not switch on or 

does not respond.

Check if the plugs are properly connected and undamaged, or try 

different power socket.

The Air Cleaner automatically 

switches between modes.

Check if the motion sensor is dirty and if so clean it.

The fan makes an unusual noise.

Unplug the product, wait 60 seconds, remove the filter and check for 

possible obstructions in or around the filter.

The air quality remains bad 

(red LED).

Ventilate the room until the air quality improves or replace the filter.

The Air Cleaner produces strange smells.

Check the filter and replace if necessary.

5.

Troubleshooting

Always remove the plug from the socket before removing the filter. Do not attempt to 

repair or disassemble the product yourself.

Problem

Solution

4.

Operating the Air Cleaner

The Air Cleaner has 4 modes and is operated with 

hand gestures. Move your hand above the sensor 

located in the front, on top of the Air Cleaner. Hold 

your hand over the sensor for 3 seconds to turn the 

Air Cleaner on/off, and briefly move your hand over 

the sensor to move to the next mode. The different 

modes are described here.
In normal circumstances its recommended to use 

the Air Cleaner in automatic mode or at fan mode 1, 

when you are experiencing discomfort due to 

allergens, asthma or high levels of contaminants 

in the air use fan mode 2.

ON

OFF

Fan mode 1

Fan speed normal.

LED

Fan mode 2

Fan speed fast.

LED

Operation dependent on measured air quality.

Automatic mode

LED

Silent/sleep mode

Fan speed normal and LED’s off.

LED

Hold hand above the sensor for 3 seconds.

Hold hand above the sensor for 3 seconds.

Air Cleaner on

Air Cleaner off

 

(possible during any mode)

Movement 

sensor

PlasmaMade

 Air Cleaner - TAC120

7.

Discard and recycling

The Air Cleaner must not be disposed with normal household waste. 

To dispose of the Air Cleaner follow the applicable regulations in your 

country.

Summary of Contents for TAC120

Page 1: ...PT EN DA DE NO FR SV ES FI IT Table Air Cleaner TAC120 Create your own clean bubble NL...

Page 2: ...nants over time and should be replaced at least every 6 months For information on replacing the filter see chapter 3 Using the Air Cleaner The Air Cleaner is equipped with a sensor that measures the c...

Page 3: ...ntreinigingen en moet minimaal om de 6 maanden vervangen worden Voor informatie over vervanging van het filter zie hoofdstuk 3 Gebruiken van de Air Cleaner De Air Cleaner is voorzien van een sensor di...

Page 4: ...e ausgetauscht werden Informationen zum Austausch des Filters finden Sie in Kapitel 3 Verwendung des Air Cleaners Der Air Cleaner ist mit einem Sensor ausgestattet der die Konzentration von VOC fl cht...

Page 5: ...iltre du purificateur d air se colmate avec le temps et doit tre remplac au moins tous les 6 mois Pour des informations sur le remplacement du filtre voir le chapitre 3 Utilisation du filtre air Le pu...

Page 6: ...leaner est equipado con un sensor que mide la concentraci n de VOC compuestos org nicos vol tiles en el aire y determina as la calidad del aire En el modo autom tico el ventilador se controla en funci...

Page 7: ...3 Usando il Air Cleaner Il filtro dell aria dotato di un sensore che misura la concentrazione di VOC composti organici volatili nell aria e determina la qualit dell aria con tali informazioni In modal...

Page 8: ...bter informa es sobre a substitui o do filtro consulte o cap tulo 3 Usando o purificador de ar O Purificador de Ar est equipado com um sensor que mede a concentra o de VOC compostos org nicos vol teis...

Page 9: ...l 3 Brug af luftrenseren Luftrenseren er udstyret med en sensor der m ler koncentrationen af VOC flygtige organiske forbindelser i luften og bestemmer luftkvaliteten med den information I automatisk t...

Page 10: ...fullt av forurensninger og b r skiftes ut minst hver 6 m ned For informasjon om utskifting av filteret se kapittel 3 Bruk av luftrenseren Luftrenseren er utstyrt med en sensor som m ler konsentrasjone...

Page 11: ...st var sj tte m nad F r information om byte av filter se kapitel 3 Anv nda luftrenaren Luftrenaren r utrustad med en sensor som m ter koncentrationen av VOC flyktiga organiska f reningar i luften och...

Page 12: ...ttava v hint n 6 kuukauden v lein Katso lis tietoja suodattimen vaihtamisesta luvusta 3 Ilmanpuhdistimen k ytt minen Ilmanpuhdistin on varustettu anturilla joka mittaa VOC pitoisuuden haihtuvat orgaan...

Page 13: ...1 4 7 2 5 8 3 6 9 Table Air Cleaner TAC120 PlasmaMade B V Postbus 162 7950 AD Staphorst...

Reviews: