background image

3

Pos. SHARK 45

230 V

SHARK 45

115/230 V

Descrizione

Description

13

468750

468750

Adesivo logo PLASMATECH

Sticker logo PLASMATECH

14

438103

438103

Maniglia

Handle

15

438710

438710

Manopola interruttore

Main switch knob

16

432029

432029

Filtro regolatore

Air filter

17

404370

404370

Attacco rapido ingresso aria compressa

Air inlet nipple

18

438400

438400

Manometro

Manometer

19

352377

352377

Pannello posteriore

Rear panel

20

427895

427895

Pressacavo linea

Main cable clamp

21

235942

235960

Cavo linea

Main cable

22

420483

420483

Coperchio completo logo PLASMATECH

Steel cover complete with logo 

PLASMATECH stickers

23

468750

468750

Adesivo logo PLASMATECH

Sticker logo PLASMATECH

13

14

15

16

17

18

19

20

21

22

23

Summary of Contents for SHARK 45

Page 1: ...W xxxxxx EN Operator s manual READ CAREFULLY CEA COSTRUZIONI ELETTROMECCANICHE ANNETTONI S p A C so E Filiberto 27 23900 Lecco Italy Tel 39 0341 22322 Fax 39 0341 422646 Cas Post P O BOX 205 e mail ce...

Page 2: ...ever you want to carry out a test to check that air is present A series of LEDs for indicating the cutting operating cycle and checking correct functioning of the plant Plasma torch with ignition of p...

Page 3: ...en the fused material flows through the groove and is not projected in the direction of the torch If the latter occurs cut ting speed has to be reduced The parameters that affect cutting are Electric...

Page 4: ...uses in the line with delays Table 2 Model SHARK 45 Single phase power supply 50 60 Hz V 115 15 230 15 Power input I2 Max kVA 4 8 5 5 Delayed fuse I2 100 A 25 16 Duty cycle X 40 C A 30 25 40 35 Mains...

Page 5: ...st be moved to this position whenever you want to cut AIR CHECK The switch must be moved to this position whenever you want to carry out a test to check that air is present Connection of plasma torch...

Page 6: ...f the post airflow phase the first time the pilot arc switches on this takes more time for the plant to carry out the necessary electronic and pneumatic tests 7 To start cutting press the torch button...

Page 7: ...r attention must be given to the solenoid valve and the air filter Although the air filters do not have an automatic conden sate drain it is good practice to clean the air filter insert from time to t...

Page 8: ...cally Switch off the machine by turning the power supply switch Pos 4 Fig B to position O and switch it on again after at least 5 seconds GENERAL WARNING SIGNAL yellow LED Pos 4 Fig C on and flashing...

Page 9: ...ltage 10 Before using the equipment you should carefully read the instructions included in this manual 11 Warning Risk of electric shock 12 Product suitable for free circulation in the European Commun...

Page 10: ...10 Wiring diagram 2101EA58...

Page 11: ...icambi LEGGERE ATTENTAMENTE EN Spare parts list READ CAREFULLY FR Liste pi ce de rechange LIRE ATTENTIVEMENT DE Ersatzteilliste SORGF LTIG LESEN ES Lista repuestos LEER ATENTAMENTE NL Onderdelenlijst...

Page 12: ...8296 468296 Adesivo lato connessione torcia Plasma Sticker central connection Plasma torch side 9 236621 236621 Attacco centralizzato torcia Plasma Central connection Plasma torch 10 461947 461947 Con...

Page 13: ...filter 17 404370 404370 Attacco rapido ingresso aria compressa Air inlet nipple 18 438400 438400 Manometro Manometer 19 352377 352377 Pannello posteriore Rear panel 20 427895 427895 Pressacavo linea...

Page 14: ...rch wiring 25 425944 425944 Elettrovalvola Air solenoid valve 26 453249 453249 Pressostato Pressostat switch 27 404898 404898 Basamento metallico Steel base 28 449586 449586 Telaio interno metallico S...

Page 15: ...Isolamento scheda inverter di potenza dal telaio Power inverter electric insulation from the chassis 35 377121 377121 Scheda elettronica controllo inverter Inverter control pcb 36 240241 240241 Indut...

Page 16: ...telling van reserveonderdelen Voor het bestellen van onderdelen duidelijk aangeven 1 Het codenummer van het onderdeel 2 Soort apparaat 3 Spanning en frequentie op het gegevensplaatje te vinden 4 Het s...

Page 17: ...CEA COSTRUZIONI ELETTROMECCANICHE ANNETTONI S p A C so E Filiberto 27 23900 LECCO ITALY Cas Post P O BOX 205 Tel 39 0341 22322 Fax 39 0341 422646 cea ceaweld com www ceaweld com...