background image

 

DNET - 

DINGO ETHERNET GATEWAY 

Rev 2.2

 

The DNET Ethernet Gateway is designed for use with the Dingo series of solar charge controllers. It 
provides basic read-only access to the main parameters of the Dingo 2020N and Dingo 4040P products via 
both a Web Server interface (HTTP) and the Simple Network Management Protocol (SNMP)  

Configuration 

A configuration mode is provided to allow changes to the default settings. This mode is enabled by a short 
press (less than one second) of the 

Configuration Button

 within 10 seconds of applying power to the 

device.  See Figure 1 below. 

 

 

Figure 1 Ethernet Port and Configuration Button 

 

The DNET may need to be configured to work with the host network. By default the device uses DHCP to 
acquire a network IP address, failing this it will revert to Link Local Addressing. 

By connecting the DNET directly to a computer using the Ethernet port it is possible to access the 
configuration web page of the DNET. It may take up to a minute for the computer to establish network 
communications with the DNET. When Ethernet communications are established it will be possible to access 
the Web Server via: 

http://169.254.100.100/config.html 

After the parameters have been configured the update button on the web page should be clicked and then 
the DNET needs to be reset by removing the power. The DNET is then configured and ready for connection 
to the host network. 

 

Web Server 

The DNET can present the status of the attached Dingo device via web pages. These can be accessed by 
using the assigned IP address directly from a web browser 

http://<IP Address>

 

/status.html

 