PLASMON LMS - LD 8100 USER MANUAL
Page 22
TEMPERATURE, HUMIDITY AND ALTITUDE
The following table lists the LD 8100 operating, nonoperating, storage and transit limits for temperature,
humidity, and altitude.
Table 2. Temperature, Humidity and Altitude Limits
1 Storage specifications are for 90 days maximum in Plasmon LMS packaging. No condensation is permitted. Transit specifications are
based on a maximum 1-week period in a factory-sealed container.
2 Maximum operating temperature is 42°C (107.6°F) for a free-standing drive at sea level unless otherwise stated. Maximum operating
temperature is derated linearly above 300 m altitude to 38°C (100.4°F) at 2,000 m altitude.
3 See the LD 8100/LF 8600/LF 8602 Product Specification (P/N 97663035) for more information concerning the temperature and humidity
operating range.
CONDITION
OPERATING
NONOPERATING
STORAGE/TRANSIT
1
Temperature
10° to 42° C
2
(50° to 108° F)
-40° to 66° C
(-40° to 151° F)
-40° to 66° C
(-40° to 151° F)
Maximum Rate of
Change
11° C/hr (20° F/hr)
20° C/hr (36° F/hr)
20° C/hr (36° F/hr)
Humidity
(Noncondensing)
10 to 99%
5 to 95%
5 to 95%
Maximum Rate of
Change
10%/hr
10%/hr
10%/hr
Maximum Wet Bulb
Temperature
3
28° C (82° F)
46° C (115° F)
46° C (115° F)
Minimum Dew Point
2°
C (35.6° F)
2°
C (35.6° F)
2°
C (35.6° F)
Altitude
-300 to 3000 m
(-984 to 9840 ft)
-300 to 3000 m
(-984 to 9840 ft)
Storage:
-300 to 3000 m
(984 to 9840 ft)
Transit:
-300 to 12,000 m
(-984 to 40,000 ft)