VIEWING DIAGNOSTIC RESULTS OR PERFORMING DIAGNOSTIC
OPERATIONS ("DIAGNOSTICS")
To enter the diagnostic submenu, press the TEST/SELECT switch while "Diagnostics" is displayed in the
Main menu. The drive will enter the Diagnostics menu which includes the following options:
"Park Drive"
Press the SELECT switch to park the baseplates for drive shipment. If the
"Park Failed, Close Manually" message appears, refer to the Manual Release
section of this manual. Press the MENU switch to select the next option in the
Diagnostics menu.
"Test Sensors"
Press the SELECT switch to enter sensor display mode. In sensor display
mode the DOC panel will display the status of the sensors within the drive.
For details, see the LD 8100 Hardware Maintenance Manual (P/N 97663081).
Press the MENU switch to select the next option in the Diagnostics menu.
"Clear NvRAM"
CAUTION
Since the initialization variables cannot
be recovered once they are cleared, this
operation should only be performed by a
trained Customer Engineer (CE).
Press the SELECT switch; the message "Drive will reset and NvRAM will be
cleared! To Continue Press Select" will appear. Press the MENU switch if you
do not want to clear the nonvolatile memory (NvRAM) initialization variables;
press the SELECT switch to clear the NvRAM initialization variables in the
drive. Press the MENU switch to select the next option in the Diagnostics
menu.
"View CDEs"
Press the SELECT switch to view the controller detected error (CDE). The
DOC will display the error code. When no error has occurred, the "No CDE
Error" message is displayed. The error code is cleared upon exiting the
Diagnostics menu. The error code should be logged by the operator for aiding
the CE in diagnosing the drive problem. Press the MENU switch to select the
next option in the Diagnostics menu.
"Baud:"
Press the SELECT switch to cycle through the available baud rates. When
the desired is displayed, press MENU to go to the next menu item.
"Test Start:"
Press the SELECT switch to select the Test to be performed (0 - 9). Once the
desired test has been selected, press MENU to select the Test End value
(see the next table for the test value and test name).
"Test End:"
Press the SELECT switch to select last Test to be performed (0 - 9). Once the
desired test has been selected, press MENU to select the Test Cycle value
(see the next table for the test value and test name).