Appendix D
Plasmon D875 - D2175 User Manual
Page 78
Document Revision E
80
1
Element not
present
Checking move from an
invalid fixed slot loca-
tion
Correct host software
2
Checking move to an
invalid fixed slot loca-
tion
3
SCSI position attempt
to an invalid slot loca-
tion
81
1
Magazine not
present
Magazine not present
during verification of
installation
Replace magazine
2
Magazine not present
during recovery
84
1
Source is empty
Online check of
NVRAM says source
element is empty
Run Check Elements, Host
needs to check inventory
2
Online check of
NVRAM says source
element is empty, to
element is full (not
exchange command)
3
Src element = 1st desti-
nation element during
exchange command
85
1
Destination is full Online check of
NVRAM says destina-
tion element is full (not
an exchange com-
mand)
Run Check Elements, Host
needs to check inventory
2
Online check of
NVRAM says destina-
tion element is full
(picker address not
zero)
3
1st destination element
= 2nd destination ele-
ment during exchange
command
Error
Code
(hex)
Sub-
code
Error
Description
Subcode
Description
Compo-
nent
Corrective Action
Summary of Contents for LIBRARIES D2175
Page 1: ...The Plasmon Enterprise D Series D875 D2175 Libraries DVD Drive User Manual P N 97704577 E ...
Page 2: ......
Page 10: ...List of Figures Plasmon D875 D2175 User Manual Page 8 Document Revision E ...
Page 12: ...List of Tables Plasmon D875 D2175 User Manual Page 10 Document Revision E ...
Page 40: ...Library Installation Plasmon D875 D2175 User Manual Page 38 Document Revision E ...
Page 52: ...Menu System Plasmon D875 D2175 User Manual Page 50 Document Revision E ...
Page 56: ...Appendix A Plasmon D875 D2175 User Manual Page 54 Document Revision E ...
Page 62: ...Appendix B Plasmon D875 D2175 User Manual Page 60 Document Revision E ...
Page 90: ......