PLATINUM Inverter 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL
Mounting
22
Installation and operating manual: PLATINUM Inverter 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL
Version 05/2010
Mat. No. 734 559-AB
Terminal strip connectors
Fig. 10 Layout of terminal strip connectors
(1) Alarm contact (break contact)
(2) Alarm contact (center contact)
(3) Alarm contact (NO contact)
(4) not allocated
(5) Input, max. 12 V (option)
(6) Supply voltage for ext. consumer 12 V,
max. 300 mW
(7) Supply voltage for ext. consumer 0 V,
(8) Shielding EIA485 (RS485)
(9) Line A of EIA485 bus line
(10)Line B of EIA485 bus line
(11)Line A of EIA485 bus line
(12)Line B of EIA485 bus line
Note
Terminal strip is protected through cover Opening the cover is
possible without tools.
DIEHL Controls recommends to use connectors if EIA485 bus line as
follows:
Î
For incoming line pair:
t
connector 9
t
connector 10
Î
For outgoing line pair:
t
connector 11
t
connector 12
11 2 3 4 5 6 7 8 9 101112
PLATINUM Wechselrichter TL_GB.book Page 22 Thursday, August 19, 2010 2:38 PM