13
OPERATING INSTRUCTIONS
LIGHTING INSTRUCTIONS
2
Incorrect placement of logs:
Correct placement of logs:
NOTE:
Remove mesh cover (B) and cooking grid (C) when lighting wood with the Fireshot Ignition
System™
.
1. Place logs in fire bowl. Do not burn more than 7 lbs / 3.18 kgs of wood or fire logs in the fire pit.
CAUTION:
Do not attempt to operate until you have read and understand all General Safety
information in this manual and all assembly is complete and leak checks have been performed.
2. Position logs so that they do not block the burner. Place mesh cover (B) over fire bowl.
5. Apply several drops of solution where valve connects
to corrugated pipe and where corrugated pipe
connects to burner. Push and turn the gas control
knob to release propane gas into the connections.
Turn the knob to (FLAME) and then immediately
turn knob to O (OFF). Only do this operation once.
The burner may light for a moment while the gas passes
through the connections. See if bubbles appear.
(Figure 2)
If Bubbles appear at any connection, there is a leak.
1. If leak is at cylinder / regulator connector: Disconnect
cylinder, reconnect and perform another leak test.
2. If leak is at corrugated pipe / Regulator / control valve /
burner: Tighten connection and perform another leak test.
3. If you continue to see bubbles after several attempts,
that means that the regulator, corrugated pipe, or
control valve are defective. Call 1-877-447-4768,
8:30AM - 4:30PM CST, Monday - Friday.
If no bubbles appear at any connection, the connections are secure.
Note: Whenever gas connections are loosened or removed, you must perform a complete leak test.