customerservice@ghpgroupinc.com
5
7077-801F • 08/20
A. Appliance Safety Certification
B. Appliance Emissions Certification
NOTE:
This installation must conform with local codes.
In the absence of local codes you must comply with the
ASTM E1509-04, ULC S627-00, (UM) 84-HUD
,
Model Number:
PH35PS-B,PH50PS-B,
PH50CABPS-B
Laboratory:
UL LLC
Report Number.
MH60687
Type:
Solid Fuel Room Heater/Pellet Fuel
Burning Type
Standard:
ULC S627-00 Room Heater Pellet
Fuel Burning type and (UM) 84-HUD,
Mobile Home Approved.
This pellet heater needs periodic inspection and repair for
proper operation. It is against federal regulations to operate
this pellet heater in a manner inconsistent with operating
instructions in this manual.
PH35PS-B
PH50PS-B
PH50CABPS-B
EPA
Certification
Number:
Number: N.A.
Number: N.A.
EPA Certified
Emissions:
0.7 g/hr
1.2 g/hr
*LHV Tested
Efficiency:
79.4%
81.1%
**HHV Tested
Efficiency:
74.6%
75.9%
***EPA BTU
Output:
6,800 to 26,000 /hr 6,900 to 34,100 /hr
****BTU
Input:
9,600 to 33,200 /hr 9,800 to 44,400
/hr
Vent Size:
3 or 4 inches, “L” or “PL”
Hopper
Capacity:
40 lbs.
80/120 lbs.
Fuel:
Premium Wood Pellets
* Weighted average LHV (Low Heating Value) efficiency
using data collected during EPA emissions tests in
accordance with the requirements of CSA B415.1.
** Weighted average HHV (High Heating Value) efficiency
using data collected during EPA emissions tests in
accordance with the requirements of CSA B415.1.
*** A range of BTU outputs calculated using HHV efficiency
and the burn rates from the EPA tests.
**** Based on the maximum feed rate per hour multiplied
by approximately 8600 BTU’s which is the average BTU’s
from a pound of pellets.
Model
Number:
PH35PS-B
PH50PS-B
PH50CABPS-B
Laboratory:
OMNI Test
Laboratories, Inc.
PFS-TECO
Report
Number:
0061PS095E
19-470
Standard:
Method 28R, ASTM E1509-04 and
ASTM 2779
C. BTU & Efficiency Specifications
The PH35PS-B, PH50PS-B & PH50CABPS-B
is Certified to comply with 2020 particulate
emission standards.
1
1
Listing and Code Approvals