34
GFCI OUTLETS
A ground fault circuit interrupter (GFCI) 110-volt receptacle
located on the lower driver side ottoman provides protection
against line-to-ground electrical shock hazards that could be
harmful or even fatal. The outlets that are on this circuit are the
exterior, kitchen and rear bench receptacles.
The GFCI receptacle must be tested at least once a month in
accordance with the manufacturer’s instructions.
The GFCI for the fridge is found on the driver side ottoman face
above the LP/CO gas detector.
The GFCI for the microwave is found in the:
TS -
cabinet above the Blu-ray player
FL -
in the closet above the closet rod.
FL
TS
NOTE:
The circuits must be powered to test or reset the
GFCI. Check the GFCI for the individual appliance or plug
outlets if the appliance is not operational.
AC ELECTRICAL DISTRIBUTION PANEL
The Pleasure-Way Plateau is equipped with an AC distribution
panel that houses the breakers for the 110-120 volt system.
The distribution panel is located on the driver side ottoman
bench face. The breakers act like a household breaker; you
must insure the breaker is shut all the way off before you can
reset the breaker.
1. 15 Amp Fridge (GFCI Protected)
2. 30 Amp Input Inverter
3. 20 Amp A/C
4. 30 Amp Shore Power
5. 30 Amp Inverter Output
6. 20 Amp Microwave (GFCI Protected)
7. 15 Amp All Receptacles (GFCI Protected)