Technical manual – Installation instructions and start-up X-RAY R - ver. 1.0 del 07/11/2018
COLLECTOR X-RAY R
WITHOUT THIRD INTEGRATED PIPE AND PARALLEL DISTRIBUTION
The X-RAY R solar collector has the third pipe completely integrated in the head and three lateral hydraulic connections
that allow the hydraulic distribution in parallel on each module of the string.
The collector also has probe holders on both sides to make the connection of the external pipes reversible, both from
the right and from the left. The adductions, regardless of the number of collectors, must be made as below:
NB
In particular, the cold pipe must be connected to the high connection and the hot pipe to the low connection; the temperature
probe. It must be connected to the cockpit on the same side as the connections.
The inversion of the connections makes it impossible to correctly control the temperature and therefore the use of the solar
field.
LEFT HAND CONNECTION
RIGHT HAND CONNECTION
BASIC
Connect the adduction pipe coming from the thermal plant on the right side of the collector battery. Connect
the return pipe (cold side) to the top connection of the first manifold (the first from the right), plug the central
connection and connect the delivery (hot side) to the low connection. On the last string collector connect the
180 ° curve between the first and the second fitting, plug the third (lower part).
Place the temperature probe in the probe holder of the first collector (the first from the right).
RIGHT SIDE CONNECTION