43
Technical manual – Installation instructions and start-up X-RAY R - ver. 1.0 del 07/11/2018
Alternatively, connect the collectors to several parallel rows, making the hydraulic connections in a
balanced manner, as shown below.
The X-RAY R collectors must be connected to the input and return tubing by means of the flexible
connection (input) kit. This holds firm for both sloping and flat roofs.
The connection kit allows for the units of two collectors to be joined and, at the same time, to insulate and
protect the joint. The kit comprises a protective aluminium profile and a thermal insulating band. After
installing the collectors, assemble the connection kit according to the following steps.
HYDRAULIC CONNECTIONS
INSTALLATION OF CONNECTION KIT – SIDE CONNECTORS
It is advisable to provide for the arrangement of several probes, on the respective collector strings, in
order to interchange them in the event of a fault and to be able to check the correct balancing of the
circuit in conditions operational.
>
1
2
3
1030901103
HYDRAULIC
CURVE
¾’ – ¾’
1030908561
FITTING
¾’M-COPPER
22
1030908591
NIPPLE
¾’ F – ¾’ M
---
ADDUCTION
KIT
1030908571
FITTING
¾’M-COPPER
28
1030908601
NIPPLE
¾’ M – 1’ F
1030908551
FITTING
¾’M-COPPER
18
1030908581
NIPPLE
¾’ M – ¾’ M
1030905242
HYDRAULIC
COMPENSATOR
¾’