Connect the product
1
NOTE!
During installation the Dimmer 1-10 V
outputs are not activated.
Use the app to configure before use.
Based on normal cable lengths and commonly
available light fixtures on the market.
*
Install the product in an appliance box or on a bracket
(not provided, MNT-01) on a DIN rail or wall.
CTR-01 has a relay with an interrupting rating of 16 A with
a resistive load however different loads have different
input current when switching on and voltage spikes when
switching off. The preceding table is recommended for
different types of lighting loads in order to minimise the
risk of reducing service life.*
Maximum current 16 A.
Control inputs 1 and 2 can be used for control using e.g.
- Push-button (preset)
- Light switch
- Motion sensor (with neutral conductor)
The inputs can also be used to wirelessly control one
or more products from Plejd. A double click can be used
to activate lighting scenarios.
The settings are easy to adjust in the app.
Control via control inputs
1 2
Load
PF Rated output
VA
A
Halogen (230 V)
1
3 500W
3 500 16
LED loads
0,9
800W
1 000
4
Fluorescent tube uncompensated
0,3
700W
2 300 10
Fluorescent tube compensated
0,85
1 500W
1 750
8
Low voltage halogen electronic
0,8
1 500W
1 750
8
Low voltage halogen conventional 0,95
1 200W
1 200
5
Low-energy bulbs
0,6
500W
800
4
Support
Download the Plejd app via the App Store or Google Play.
After supplying power to the unit based on one of the
wiring diagrams, you can use the app to install the lighting.
This requires Internet connectivity and Bluetooth
®
on your
phone/tablet. You do not need any additional equipment
to get started.
With the help of the app, it’s simple to configure all
relevant settings. The app can be used to schedule
the lighting using the astronomical clock or timer, control
lighting, and wirelessly sync control switches and scenarios.
Download the app and follow the instructions
Hand over the Plejd system
Hand over the Plejd system to your customer by writing
the system code on the included sticker . You’ll find the
code in the app once you have completed the installation.
Place the sticker in the distribution box and give the
welcome folder to the customer.
2
3
In the event of any technical questions, please contact
Plejd customer services.
E-mail: support@plejd.com | Phone: +46 (0)10 203 89 91
HI!
N
1 2
L
N
0-10V bus
Koppling för 0-10V bus
(utan brytning av
matning till last)
L L
Koppling för 1-10V bus
(med brytning av
matning till last)
N
1 2
L
N
1-10V bus
L
Last
N
L L
CTR-01
Koppling för
icke-dimbar last
(endast brytning av
matning till last)
L
N
N L
1 2
L
N
1 2
L
N
0-10V bus
Koppling för 0-10V bus
(utan brytning av
matning till last)
L L
Koppling för 1-10V bus
(med brytning av
matning till last)
N
1 2
L
N
1-10V bus
L
Last
N
L L
CTR-01
Koppling för
icke-dimbar last
(endast brytning av
matning till last)
L
N
N L
1 2
L
Coupling for 0-10 V bus
(without switching off
load to power supply)
Coupling for 1-10 V bus
(with switching off load
to power supply)
Coupling for
non-dimmable load
(only swithing off load
to power supply)
1-10 V bus
0-10 V bus
N
1 2
L
N
0-10V bus
Koppling för 0-10V bus
(utan brytning av
matning till last)
L L
Koppling för 1-10V bus
(med brytning av
matning till last)
N
1 2
L
N
1-10V bus
L
Last
N
L L
CTR-01
Koppling för
icke-dimbar last
(endast brytning av
matning till last)
L
N
N L
1 2
L
Load