background image

8

  

  

PLINIUS REFERENCE M-10

4. INPUT SELECTION SWITCH

This switch directly above the XLR input is used to select the pair of RCA or XLR input 
sockets UP towards the RCA selects the RCA input connections, while DOWN selects XLR 
inputs.

5. HT BYPASS INPUT

This input is for use specifically with home theatre processors and AV receivers. In some 
circumstances you may wish to use the Plinius system as the front two channels of a 
surround or home theatre environment. The HT Bypass input can be used for this purpose, 
as any signal connected to these inputs will feed to the outputs, bypassing the volume 
control. HT Bypass mode is accessed by the remote or the trigger input.

6. PRE OUT 

The Pre Out connection is provided to enable the Reference M-10 dual mono preamplifier 
to be connected to an external power amplifier.  

7. LINE OUT

These RCA outputs are situated next to Pre Out and are provided to interface to line level 
recording devices for archiving, or transferring to portable media. The outputs are always 
live with the signal of whichever source is selected at the time of recording.

8. REMOTE TRIGGER INPUT/OUTPUT SOCKETS

In order to integrate more effectively into a home theatre system, the Reference M-10 
has a remote trigger input socket on the rear panel. By connecting a processor or source 
component with a remote trigger signal to this socket, the Reference M-10 can be 
switched between HT Bypass and standby modes. When in standby the preamplifier draws 
less current and will operate at minimum temperature. This may be of advantage in multi-
amplifier and/or remote installations.

The Reference M-10 also features two remote trigger output sockets. By connecting this 
trigger output to other system components, the entire system can be put in and out of 
standby by the source component.

9. REMOTE IR INPUT

This socket is for connecting to an external remote control sender. Some companies 
manufacture these devices to enable multi-room remote control. Please see your Plinius 
dealer for further advice. 

10. GROUND LIFT SWITCH 

This switch allows the signal ground to be disconnected from the chassis.  In some 
installations a hum loop may exist due to duplicate ground paths from different 
equipment.  Use this switch to remove the connection from 0V to ground thus allowing 
some flexibility in your particular set-up.

Summary of Contents for Reference M-10

Page 1: ...stallation Operation 11 Product Features 14 Troubleshooting 16 Specifications 17 Index 18 All operational technical and descriptive material in this publication is subject to change at any time withou...

Page 2: ...ign and the variety of ways it may be used We have designed and manufactured this preamplifier to reproduce your favourite music faithfully and accurately With a little care and a full understanding o...

Page 3: ...any way Equipment racks should be of an open type with no closed side panels and no closed front or rear panels Ensure a minimum of 100mm clearance on all sides of your Plinius unit to other equipment...

Page 4: ...ch or a switch setting is not used it is a good idea to toggle small switches and turn rotary switches though the full range of the switch several times in succession to keep the contacts active Perfo...

Page 5: ...g removal of the lid be referred to a suitably qualified and experienced service technician DO NOT attempt to connect any input of this preamplifier to its own outputs DO NOT earth any output terminal...

Page 6: ...Ds communicate the current source selection 4 HT BYPASS LED This small white LED is ON when the current source selection is the HT Bypass Input This input can be selected using the remote control or a...

Page 7: ...on and off repeatedly 2 INPUT TERMINALS The input terminals for your Plinius Reference M 10 dual mono preamplifier are easily accessible along the top of the rear panel with the right channel red inpu...

Page 8: ...at the time of recording 8 REMOTE TRIGGER INPUT OUTPUT SOCKETS In order to integrate more effectively into a home theatre system the Reference M 10 has a remote trigger input socket on the rear panel...

Page 9: ...in distortion levels and can assist where multiple instances of XLR connections result in too much gain in the complete system 12 MAINS POWER CORD IEC SOCKET This connector is where the mains supply c...

Page 10: ...the volume Briefly press either button to make fine adjustments to the volume level Hold down either button to continually adjust the volume level Adjusting volume UP will also take the preamplifier...

Page 11: ...0 dual mono preamplifier using suitable single ended RCA or Balanced XLR interconnect cables only For RCA make sure you connect the red coded cable to the red RIGHT RCA input and the white cable to th...

Page 12: ...from whatever source is currently selected All pre out outputs are live at all times except during Mute or Standby USING LINE OUT A line level output is provided on the back of the Reference M 10 Prea...

Page 13: ...times in case of emergency WARM UP PERIOD You will find that the Reference M 10 dual mono preamplifier will become noticeably purer in sound after being on for a period of time We usually recommend wa...

Page 14: ...ne Level output is provided to interface to headphone amplifiers line level recording devices for archiving or other accessories that require a line level signal The outputs are always live with the s...

Page 15: ...should blow you must first establish the cause of this failure such as power surges damaged mains cable etc before replacing the fuse with one of the same rating and type Should the preamplifier cont...

Page 16: ...und begins to come through the speakers Check the unit is not in Mute If the Display LED is dim this indicates the unit is in Mute mode The Display LED should be full brightness for operational mode P...

Page 17: ...nbalanced 7V RMS XLR Balanced INPUT IMPEDANCE 7 5k RCA Unbalanced 47k XLR Balanced OUTPUT IMPEDENCE 10 RCA Unbalanced 20 XLR Balanced MAXIMUM OUTPUT VOLTAGE 7V RMS RCA Unbalanced 14V RMS XLR Balanced...

Page 18: ...9 12 Input Terminals 7 11 Line Out 8 12 14 Mains Line Fuse 14 Mains Supply Connection 12 Mains Switch 7 Operating Temperature 3 Phasing 11 Placement 3 Pre Out Output 8 12 Rear Panel Layout 7 Remote Co...

Page 19: ...PLINIUS REFERENCE M 10 19...

Page 20: ...20 PLINIUS REFERENCE M 10...

Reviews: